To  compare  pressure  conditions  from  one  location  to  another,  meteorologists  correct  pressure  to 

sea-level conditions. Because the air pressure decreases as you rise in altitude, the sea-level corrected 

pressure  (the  pressure  your  location  would  be  at  if  located  at  sea-level)  is  generally  higher  than  your 

measured pressure. 

 

Thus, your absolute pressure may read 28.62 inHg (969 mb) at an altitude of 1000 feet (305 m), but the 

relative pressure is 30.00 inHg (1016 mb). 

 

The standard sea-level pressure is 29.92 in Hg (1013 mb). This is the average sea-level pressure around 

the  world.    Relative  pressure  measurements  greater  than  29.92  inHg  (1013  mb)  are  considered  high 

pressure and relative pressure measurements less than 29.92 inHg are considered low pressure. 

 

To  determine  the  relative  pressure  for  your  location,  locate  an  official  reporting  station  near  you  (the 

internet  is  the  best  source  for  real  time  barometer  conditions,  such  as  Weather.com  or 

Wunderground.com), and set your 

Opes™ Weather Station to match the official reporting station. 

 

To change the relative pressure when flashing, press the 

+

 key or 

MIN/MAX

 key to increase or decrease 

the relative pressure setting to match the official reporting station. 

 
 

5.3 Alarm Modes 

-      While in Normal Mode press the 

ALARM

 key to enter the High Alarm Mode 

-      Press the 

ALARM 

key again to enter Low Alarm mode 

Remark: after the initial pressing of 

ALARM

 key, the display will be refreshed to show current high, 

low alarm value. Normal alarm value will be displayed only for those already activated, all other not 
activated values will be displayed 

with “---“or”--“instead. 

-      Press the 

ALARM

 key again to return the Normal Mode 

-      In the High Alarm Mode press the 

SET

 key to select the following alarm modes: 

6. 

Time alarm (hour/minute) 

6. 

Indoor humidity high alarm 

6. 

Indoor temperature high alarm 

6. 

Outdoor humidity high alarm 

6. 

Outdoor temperature and dew point high alarm   

6. 

Pressure high alarm 

 
-      In the Low Alarm Mode press the 

SET

 key to select the following alarm modes: 

1.  Time alarm (hour/minute) 
2.  Indoor humidity low alarm 
3.  Indoor temperature low alarm 
4.  Outdoor humidity low alarm 
5.  Outdoor temperature and dew point low alarm 
6.  Pressure low alarm 
 

-      In the alarm modes, Press 

+

 key or 

MIN/MAX

 key to change or scroll the alarm value. Hold the 

+

 key or 

MIN/MAX

 key for 3 second to change the number in greater steps. Press the 

ALARM

 key to choose 

the alarm on or off (if alarm is enabled, the speaker icon on the LCD will be turned on indicating the 
alarm function has been enabled). Press the 

SET

 key to confirm the setting and continue pressing the 

SET

 key to toggle through each alarm mode until it returns to the normal display mode. 

-      Press 

SNOOZE/LIGHT

 key or no key for 10 seconds and the alarm mode will return to Normal Mode 

 
Canceling the Temperature Alarm While Sounding 

a. When a set weather alarm condition has been activated, that particular alarm will sound and flash for 120 
seconds. Press any key to mute the alarm. When weather alarm condition is activated again within 10 
minutes, alarm will not sound but will continue to flash until weather conditions have become more steady. 
This feature is useful to avoid repeated triggering for the same alarm value. 

Summary of Contents for OP-WS01/WH1170

Page 1: ...4 4 Examples of changing weather icons 5 4 5 Storm warning indicator 5 5 Program modes 5 5 1 Quick display mode 5 5 2 Setting mode 6 5 2 1 Setting Calibrated Humidity 6 5 2 2 Setting Barometric Pressu...

Page 2: ...he temperature from its location Every time the remote sensor is powered up for example after a change of batteries a random security code is transmitted and this code must be synchronized with the ba...

Page 3: ...at designated disposal points Never dispose of batteries in a fire as this may cause explosion risk of fire or leakage of dangerous chemicals and fumes 3 2 Mounting 1 Base station By using the foldab...

Page 4: ...unit 12 Indoor temperature and humidity alarm on indicator 13 Remote sensor transmit signal indicator 14 MIN MAX information 15 Dew point temperature display 16 Outdoor humidity display 17 Outdoor te...

Page 5: ...suit the user s requirement for storm forecasting from 3 9hPa default 4hPa When there is a fall over pressure threshold within 3 hours the storm forecasting will be activated the clouds with rain icon...

Page 6: ...solution loss due to its internal calculation algorithm 5 2 1 Setting Calibrated Humidity The display console allows you to calibrate both the indoor and outdoor humidity Humidity is a difficult param...

Page 7: ...layed only for those already activated all other not activated values will be displayed with or instead Press the ALARM key again to return the Normal Mode In the High Alarm Mode press the SET key to...

Page 8: ...will be displayed Press MIN MAX key again to return the Normal Mode Maximum Reading Reset In the maximum reading Mode press the key to display the maximum values for the readings below together with...

Page 9: ...ange batteries Temperature humidity or air pressure is incorrect Check replace batteries If multiple remote sensors are in use check location with corresponding boxed numbers Or move away from sources...

Reviews: