Opera Relieve Overlay Instructions Manual Download Page 13

12

15. 

Mattress Dimension

2000x900x130mm (5” depth)

Number of Air Cells

16 Cells

Power Control Unit Dimension

260x220x90mm

Material

Mattress Cell – 100 % nylon with TPU 

lamination
Coverlet – Quilted nylontaffeta backing

Power Input

220-240Vac, 50Hz, 0.05A

Power Consumption

Normal Operation: Max 6W

Power Control Unit Weight

2.5 kgs

Fuse Rating

T1A 250V
Class II Type B, double insulated 
IPX0, do not immerse power unit in any 

liquid or spray any liquids directly on the 

power unit.
This system is not AP/APG Protected.
Continuous operation

Power Cord

Operating & Transportation & Storage 

Conditions

Temperature:5°C~40°C
Humidity:15%~60%
Atmospheric Pressure:700~1060hPA

IEC/EN Test Standards

Safety: IEC/EN 60601-1_v3.0
EMC: IEC/EN 60601-1-2_v3

Maximum Weight Capacity

150kg

Power Unit (Air Pump) Model

SR303

Power Unit_Plastic Case rated UL 94V-0

System Name

RELIEVE Overlay Mattress System

H05VV-F or H05VVH2-F, 

2 x Min. 0.75mm

2

Product Specifications

Summary of Contents for Relieve Overlay

Page 1: ...Instructions and for Opera Relieve Overlay Mattress System Opera Care Azure House Connaught Road Hull HU7 3AP 0333 222 8584 support opera care co uk opera care co uk...

Page 2: ...ervice 11 14 Warranty 11 15 12 Thank you for purchasing this anti decubitus mattress replacement system PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE SETTING UP AND USING THE DEVICE Pay special atte...

Page 3: ...e ulcers by facilitating blood circulation and decreasing pressure of each tissue s contact area Always consult a physician or healthprofessional before using this mattress system This anti decubitus...

Page 4: ...Hazard exists This device draws air from the surrounding environment Thus cigarette smoking may damage internal components 2 4 Disinfection Between Patients This system should be disinfected thorough...

Page 5: ...l make sure to follow national state and or facility requirements for disposal of the unit 3 6 Maximum Operating Temperature The air mattress operates at a max of 100 F 37 7 C 3 7 Sharp Protrusions CA...

Page 6: ...e internal pressure of the mattress according to patient weight Simply turn the knob to adjust the pressure setting if the mattress is too soft or firm to suit each patient s needs Caregivers should a...

Page 7: ...ower Cord provided with a molded on anti kink bushing held in place by integral slot in bottom enclosure 5 Hanging Hooks Hanging hooks are designed to hang the power unit on almost any foot board 5 7...

Page 8: ...EN 60601 2 52 2010 6 2 Secure Power Unit Secure the power unit onto the foot board using hanging hooks 6 4 Connect Hose Couplers Firmly connect the air hose couplers to the couplers on the power unit...

Page 9: ...TUCKING THE BEDSHEET SHEET IN TOO TIGHTLY MAY REDUCE THE EFFECTIVENESS OF THE SYSTEM 8 Patient Transfer and Transport 8 1 Transfer It is recommended to have the mattress system fully inflated during...

Page 10: ...ying with a clean dry cloth Use only mild detergents to clean the coverlet and the mattress Any appropriate NON PHENOLIC cleaning agent may be used for heavy and coverlet are completely dry before let...

Page 11: ...ment is not and or Bottoming out is occurring and or Patient leaves a deep indentation at the contact area which does not return back to its original shape Check CPR Pull Cord Unzip mattress cover and...

Page 12: ...e production lot number has been removed or defaced on which repair has been attempted by any person or agency not authorized by our company or if in the sole opinion of our company that the system sh...

Page 13: ...insulated IPX0 do not immerse power unit in any liquid or spray any liquids directly on the power unit This system is not AP APG Protected Continuous operation Power Cord Operating Transportation Sto...

Page 14: ...in which radiated RF disturbances are controlled The customer or the user of the Air Pump can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF...

Page 15: ...1000 4 5 1 kV differential mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interrupt...

Page 16: ...Opera Care Azure House Connaught Road Hull HU7 3AP 0333 222 8584 support opera care co uk opera care co uk U 2S2301 30831 G V1 1...

Reviews: