KEYPAD MAINTENANCE 

 

Cleaning the Housing and Touchpad 

Monthly

:  

Inspect and clean the housing and touchpad on a regular basis (monthly) .  To clean   spray 

the unit with a mild soapy water solution then wipe it with a soft cloth. Do not use alcohol, harsh 
chemicals, abrasives, or petroleum-based products. Do not immerse the device in water or use a 
pressure washer.  
 

Yearly

:

  Open the keypad, inspect and clean the inside of the unit.  Remove dirt or dust that has collected 

on  the  inside  of  the  housing  and  the  circuit  board  that  could  cause  problems.  Note  any  signs  of  water 
damage  or  corrosion caused  by a  leak  in  the  enclosure  seals.  Replace  any  worn  seals. A  small  can of 
compressed air can be used to remove insects and dust from the circuit board. 
  

 

 

 
NOTICES and DISCLAIMERS 
 

Liability Disclaimer

: While every effort has been made to ensure the accuracy of the information in this document,  

and  we  assume  no  liability  for  any  inaccuracies  contained  herein.  We  reserve  the  right  to  change  the  information 
contained herein at any time and without notice.   

FCC Part 15 Notice

: This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part  15  of  the  FCC Rules.  These  limits  are  designed  to  provide reasonable  protection against  harmful 
interference in a residential installation. This equipment can generate and radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause harmful interference to radio communications.    

Summary of Contents for INSOMNIAC CIA K-500

Page 1: ...INSOMNIAC CIA K 500 Keypad Installation Manual P N CIA 575 001 Revision 1 0 Date Code 1 1 2018 ...

Page 2: ...ations 7 Wireless Communications Optional 7 Relay Outputs 8 Inputs 8 Speaker and Call Button 8 Intercom 8 Earth Ground 8 Pinhole camera Option 8 Testing Troubleshooting the Keypad 9 Accessing the Display PCB and Push Button Sub assembly s 10 KEYPAD MAINTENANCE 11 Cleaning the Housing and Touchpad 11 NOTICES and DISCLAIMERS 11 Liability Disclaimer 11 FCC Part 15 Notice 11 ...

Page 3: ...ONE 8 TIME FORMAT 12 OR 24 HOUR 9 DATE FORMAT SELECTABLE 10 FORM C RELAY OUTPUTS 2 11 SECURE COMMUNICATIONS YES 12 TAMPER INTERNAL OPT EXTERNAL 13 AUXILIARY INPUTS 4 OPTO ISOLATED 14 WIEGAND INTERFACE 1 15 BLE IBEACON OPTIONAL COTS 16 CAMERA OPTION OPTIONAL IP ANALOG 17 MAX OPERATING VOLTAGE 24VDC 18 MIN OPERATING VOLTAGE 12 VDC 19 MAX INPUT CURRENT 2A 20 MAX ACCESSORY CURRENT 40 A 12VDC 20 A 5VDC...

Page 4: ...the central controller Please refer to the user s manual for the controller in conjunction with this manual Similarly mounting height and locations for keypads must match local codes regarding handicap access emergency as well as other regulations Please see Appendix A for details for common practice mounting diagrams and ADA driven mounting requirements Physical Installation and Mounting The foll...

Page 5: ...e necessary wires through the wire hole on the back of the housing Allow ample wire to remain inside the housing After the wire connections are complete excess wire can be pushed back into the gooseneck or wall or it can be carefully positioned inside the keypad housing for future maintenance and service Gate Door PWR RS485 Inbound Intercom Camera Mounting Holes 3 Ground wire PWR RS485 Outbound Fi...

Page 6: ... cables other than the RS485 Cables must be less than 10 meters long The R485 wires should be 18 gauge Other wires must be between 16 and 26 Gauge wire WIEGAND Inteface Enlarged View of Common Connection Points From Previous RS485 Device To Next RS485 Device RS485 Power Digital Inputs Relay Outputs Intercom Speaker Note Only LEF Single Master Station will have 3rd wire GRN Call Switch To Gate Oper...

Page 7: ...connection is necessary If they are tight rock them slightly back and forth while lifting away from the board 3 Insert wires into the desired connector Where 2 wires are tied together ensure that both wires are seated all the way inside the slot Use a flathead precision screwdriver to tighten down the terminal screw 4 Verify that the terminal slot has tightened down on the copper wire and not on t...

Page 8: ...PCB provides a simple way to attach the intercom cable to the speaker and the call button Typically 2 wires are only present although a 3rd can be present With two wires the interface supports both Aiphone LEF and NEM systems The 3rd wire green if present is to be wired to the E connection along with the black wire Earth Ground The earth ground wire should be To connect the ground wire run an insu...

Page 9: ...also multiple LEDs as shown below that should be active as described for troubleshooting purposes Main Fuse 2A Littelfuse Inc 39512000440 Voltage Present LEDs all 3 must be lighted RS485 Active LEDs must be flashing Micro Controller Running must be oscillating WEIGAND LED RELAY STATE LEDs INPUT STATE LEDs Figure 5 Check the 3 Power LEDs on the Keypad PCB If all are dark check replace the PCB fuse ...

Page 10: ...n be easily changed after removing the ribbon cable that connects them to the Main PCB The Display PCB mounts to a plastic carrier that also acts to hold the display window in place The carrier can be removed with 4 screws to access the window and the window seal gasket The Speaker is held in place with a retainer with 4 nuts Its face is rubberized and does not need an additional seal A plastic co...

Page 11: ...any worn seals A small can of compressed air can be used to remove insects and dust from the circuit board NOTICES and DISCLAIMERS Liability Disclaimer While every effort has been made to ensure the accuracy of the information in this document and we assume no liability for any inaccuracies contained herein We reserve the right to change the information contained herein at any time and without not...

Reviews: