All of this is configured as one Entry in the Openpath Control Center. We recommend
matching port numbers (READER 1 with CONTACT 1, for example). When setting up
Sites in the Control Center using Quick Start, Entries will default to matching READER 1
with CONTACT 1, RELAY 1, and so on. For more complex Entry setups, you’ll need to
manually add Controls to the Entry. For the example above, you’d need to add an
additional Entry/Exit Hardware Control to the Entry. For more information, refer to the
Openpath User Guide
.
WIRING THE REX WITH THE DOOR STRIKE
Except where required by fire or safety codes, for convenience you can wire the REX
in parallel with the Door Strike on the same Relay output. You can wire additional
REXs to the REX inputs on the ACU, as shown in
figure 10
.
Figure 11 : Wiring the REX with the Door Strike
Version 1.8
©
Openpath 2020
Page 17