![OpenEye OE-ENVR16 User Manual Download Page 38](http://html1.mh-extra.com/html/openeye/oe-envr16/oe-envr16_user-manual_1639839038.webp)
33086AA
39
Sensor Setup
1.
Set the Sensor
TYPE
to
N/O
(Normally Open) or
N/C
(Normally Closed).
2.
Repeat for all sensors.
3.
Click
SAVE.
Alarm Setup
1.
Enable or disable the
SIGNAL
(
ON / OFF
).
2.
Set each alarm
TYPE
(
NO / NC
).
3.
Repeat for all relays.
4.
Click
SAVE
.
Power Off
The
POWER OFF
option is a preset function that triggers an alarm relay when the recorder
loses power. This function is preconfigured to set alarm relay No. 1 to
ON
and
N/C
. When a
power loss occurs, alarm relay No. 4 will open. When power is restored the alarm will close.
S.M.A.R.T. Alarm
The
S.M.A.R.T. ALARM
option is a preset function that triggers an alarm relay when the
HDD exceeds the temperature threshold configured on the
SYSTEM > DISK SETUP >
S.M.A.R.T.
page. This function is preconfigured to set an alarm relay to
ON
and
N/C
. When
the HDD exceeds the temperature threshold, the alarm relay will open. When the temperature
is at a safe level again the alarm will close.
SET
and
CLEAR
are used to test the alarm relay operation.
SET
is used to
manually activate all relays that are set to
ON
.
CLEAR
is used to manually
deactivate all relays.
Hold Video Loss
When set, the alarm will stay on when a channel loses video. The alarm will turn off when
Video returns.