Press the
button to select a desired mode shown below:
3.
Adjust Temperature
The temperature can be set within a range of 15°C to 31°C by 1°C.
Press
or
buttons to increase or decrease the temperature 1°C by pressing once
The unit LED shows the target temperature for 5 seconds and then displays the room temperature.
4.
Adjust Fan Speed
Press the
button to select a desired fan speed shown below:
5.
Stand-by
When you press
button again, the unit will emit “di” and stop working.
Notice:
Each mode working principle:
*
Mode:
1. Once the
Operation is selected, the indoor temperature sensor operates automatically to select the
desired operation mode with
or
.
2. When the room temperature
, the unit will automatically select
mode.
3. When the room temperature
, the unit will automatically select
mode.
*
Mode:
1. The up centrifugal fan will run at low speed, and the speed can’t be adjusted.
2. the compressor and the down centrifugal fan will stop after running 8 minutes, then run again after 6 minutes.
3. The unit adopts constant temperature dehumidifying mode, and the adjustment of temperature is no effective.
*
Mode:
1. When the room temperature is higher than set temperature, the compressor will start to run.
2. When the room temperature is lower than set temperature, the compressor stop and upper fan operate at
original set speed.
*
Mode:
1.the up centrifugal fan runs at set speed, and the compressor and down centrifugal fan does not run.
2.the adjustment of temperature is no effective.