CONTENTS 

 

Electrical Specifications 

1.

 

All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If 

you have any questions regarding to the following instructions, contact a qualified electrician. 

2.

 

Check available power supply and resolve any wiring problems before installation and operation of this unit. 

3.

 

For your safety and protection, this unit is grounded through the power cord plug when plugging into a 

matching wall outlet. If you are not sure whether the wall outlet in your home are properly grounded, please 

consult a electrician. If supply   cord is damaged, it must be replaced by the manufacturer, its service agent or 

similarly qualified person in order to avoid any hazards. 

 

IMPORTANT SAFETY INSTRUCTIONS  

WARNING: 

To reduce the risk of fire, electrical shock or injury when using your air conditioner, following these basic 

precautions:  

1.

 

Plug into a grounded 3 prong outlet. 

2.

 

Do not remove ground prong.  

3.

 

Do not use an adapter. 

4.

 

Do not use an extension code. 

5.

 

Unplug air conditioner before servicing. 

6.

 

Use two or more people to move and install air conditioner. 

7.

 

This appliance is not intended for use by persons

including children

  with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 

concerning use of the appliance by a person responsible for their safety. Young children should be supervised 

to ensure that they do not play with the appliance.. 

8.

 

Correct Disposal of this product 

This marking indicates that this product should not be disposed with other household wastes throughout the 

EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle 

it responsibly to promote the sustainable reuse of material resources. To return your used device, please use 

the return and collection systems or contact the retailer where the product was purchased. They can take this 

product for environmental safe recycling.  

 

Summary of Contents for MFP35-1280

Page 1: ...MFP35 1280...

Page 2: ...To reduce the risk of fire electrical shock or injury when using your air conditioner following these basic precautions 1 Plug into a grounded 3 prong outlet 2 Do not remove ground prong 3 Do not use...

Page 3: ...utomatic Cool Dehumidify and Fan Mode Control panel opeation Automatic Cool Dehumidifying and Fan Models operation 1 Turn on the unit a Plug in then the unit beeps once b Press the button then the uni...

Page 4: ...n mode with or 2 When the room temperature the unit will automatically select mode 3 When the room temperature the unit will automatically select mode Mode 1 The up centrifugal fan will run at low spe...

Page 5: ...s the main control board can memorize the initialization of working mode When you turn on the unit it will work as the same enactment of working mode as last time no need to reset the working mode aga...

Page 6: ...es Restarting the unit at once after operation stops or changing mode during operation you need to wait 3 minutes If the plug is taken out when you restart the appliance it will return to the original...

Page 7: ...nly for a half day during a sunny day to dry the appliance inside and prevent from going mouldy 3 Stop the appliance and pull out the power supply plug then take out the batteries of remote controller...

Page 8: ...down or set temperature reached Restart or wait for auto switch No cold air under COOLING mode Room temperature lower than set temperature 2 Machine enters into anti frost protection 1 This is a norma...

Page 9: ...not expose the unit under direct sun light o avoid surface colour fading Do not fit the unit for more than 35 or upside down while transporting Place the unit on a flat surface with less than 5 incli...

Page 10: ...ncy V Hz AC220 240V 50Hz Sounds pressure level dB A 55dB A Net weight kg 30Kg Body mm 400X387X794mm Dimension W x D x H Package mm 585X470X880mm Refrigerant R410a Applying space m 24 29m Miniature fus...

Page 11: ...tket n verkkovirtaan yhteensopivalla pistokkeella Jos et ole varma onko rakennuksen pistorasiat maadoitettu oikein ota yhteytt s hk teknikkoon Jos virtajohto on vaurioitunut se t ytyy vaihtaa vahinkoj...

Page 12: ...issa on selitetty siirrett v n ilmastointilaitteen toiminnot Valmiustila Nopeus painike ajastin l mp tila yl s painke Ajastin painike Tila painike ajastin l mp tila alas painike Lepotila painike matal...

Page 13: ...ja valitsee tai tilan 2 Kun huoneen l mp tila on laite valitsee automaattisesti tilan 3 Kun huoneen l mp tila on laite valitsee automaattisesti tilan tila 1 Keskipakoispuhallin toimii matalalla nopeu...

Page 14: ...Ohjausyksikk muistaa alunperin asetetun toimintatilan joten kun laite k ynnistet n se on automaattisesti samassa toimintatilassa kuin edellisen k ynnistyksen j lkeen Laitteen toimintatilaa ei tarvitse...

Page 15: ...lauhduttimen ja vesitankin v lill Kun kondenssiovesi on alarajaa alempana pumppu ei toimi Kun kondenssiveden m r nousee alarajan yli pintakytkin 1 k ynnist kiertovesipumpun Jos veden pinta viel nouse...

Page 16: ...etken aikaa Onko asetettu l mp tila l hell huoneen l mp tilaa Voit asettaa matalamman l mp tilan Onko puhallusaukko tukossa poista tukos Toimii mutta ei viilenn Onko ovi tai ikkuna auki Onko l hell mu...

Page 17: ...on laitteen alaosassa Suorista poistoletku ja varmista ett letkun ja oven ikkunan parvekkeen tai muun sein ss olevan aukon v lill ei ole esteit Varmista ett ilman virtausta sis notossa tai ulostulossa...

Page 18: ...pistokkeesta ennen laitteen puhdistamista huoltamista tai t ytt mist Tekniset tiedot Malli MFP35 1280 J hdytyskapasiteetti Btu h W 12000Btu h 3500W Ilmankuivausteho l h 1 8 l h J hdytys sy tt teho vi...

Reviews: