factor.
3)
Press
FUNC
button once again and release, the meter will display current clock and real power,
power factor.
4)
Press
FUNC
button once again and release, the meter will display max. line power and the
appear
time of max. line power, power factor. Press and hold
FUNC
button
for 5 seconds will clear max. line
power display during this state.
5)
Press
FUNC
button once again and release, the meter will display current clock and
accumulative
power factor,
6)
Press
FUNC
button once again and release, the meter will display total on time and total electric
charge.
7)
Press
FUNC
button once again and release, the meter will display total on time of price 1 and total
electric charge of price 1.
8)
Press
FUNC
button once again and release, the meter will display total on time of price 2 and total
electric charge of price 2.
9)
Press
FUNC
button once again and release, the meter will come back to display current time and line
voltage.
Press and hold
FUNC
button
for 5 seconds to clear
accumulative total
electric quantity
and
total
electric charge during display state of total electric charge or total electric charge of price 1 or total
electric charge of price 2.
10) LCD display ----when total electric quantity, total electric charge overflow, the OVER will flash at the
same time.
6.
SETTING CURRENT CLOCK
1)
Press
FUNC
button until the
CLOCK
displays in LCD.
2)
Press
SET
button once time, The
“
WEEK DAY
” will flash at same time, the clock change to
SET
mode. you can set the current clock now.
3)
Press
UP
button to set the “
WEEK DAY
“.
4)
Press
SET
button once time again and release, The “
HOUR
” will flash. The “
WEEK DAY
” will stop
flashing and keep display.
5)
Press
UP
button to set the “
HOUR
“.
6)
Press
SET
button once time again and release, The “
MINUTE
” will flash. The “
HOUR
” will stop
flashing and keep display.
7)
Press
UP
button to set the “
MINUTE
“.
8)
Press
SET
button once time again and release, the time come back to
CLOCK
display mode.
9)
Press
UP
button during the
CLOCK
display state, change 12-24 hour mode.
To reset incorrect time, repeat above steps.
After finish setting, plug the meter into a regular
230
Volts power outlet. Plug in an appliance that you want
to use and turn the mains power on. Now the meter begins to measure the consumption of the appliance
and detect the equipment that uses too much electricity at once.
7.
SETTING PRICE OF
COST/kWh
Press and hold
FUNC
button
for 5 seconds during display state of voltage or current or power.
1)
Setting
price 1
:
a)
Press
SET
button once and release,
SET
display, the first
digital
COST/kWh
flash, press
UP
button to set it.
b)
Press
SET
button once again and release, the second
digital
COST/kWh
flash, press
UP
button
to set it.
c)
Press
SET
button once again and release, the
third
COST/kWh
flash, press
UP
button to set it.
d)
Press
SET
button once again and release, the fourth
COST/kWh
flash, press
UP
button to set it.
e)
Press
SET
button once again and release, the
radix point
COST/kWh
flash, press
UP
button to
set it.
f)
Press
SET
button once again and release, the
weekday flash, press
UP
button to set it.
g)
Press
SET
button once again and release, the hour of
ON TIME
flash, press
UP
button to set it.
h)
Press
SET
button once again and release, the minute of
ON TIME
flash, press
UP
button to set
it.
2)
Setting
price 2
:
Press
FUNC
button once and release after finish setting price 1. Set price 2, repeat above steps.
8.
STAND BY MODE
Display of LCD will disappear without any operation after AC power off for 10 seconds. Press any key
come back to display.
9.
SPECIFICATIONS
Power supply:
230V AC, 50Hz
Max. load:
16A, 3600W