Onyx ONXC4100 Manual Download Page 8

8

Program Flow Chart

BATT/PROGRAM

SYSTEM SETTING->

ENTER

+

+

Version
HW 1.00 FW1.00

Safety Timer
ON 120 

Min 

+

+

+

Capacity Cut-Off
ON 5000mAH

Temp Cut-Off
ON   50°C  122°F

Temperature Unit
 Celsius

+

Rest Time
CHG>DCHG 10Min

ENTER

[ BATT MEMORY 1 ]
 ENTER 

SET->

BATT TYPE
LiPo 

+

+

+

BATT VOLTAGE
 7.4V 

(2S)

CHARGE CURRENT
 4.9A

+

+

Key Beep 

ON

Buzzer ON

DISCHG CURRENT
 2.2A

+

DISCHG VOLTAGE
 3.0V/CELL

– +

BATT/PROGRAM

BATT MEMORY

ENTER

– +

– +

START/ENTER > 3 seconds

[ BATT MEMORY 1 ]
C:4.9A D:2.2A 

ENTER

[ BATT MEMORY 1 ]
LiPo 7.4V 

(2S)

SAVE PROGRAM
SAVE...

SAVE PROGRAM
 ENTER

+

TVC=YOUR RISK
 4.2V

+

ENTER CHARGER
LOAD...

LiPo BALANCE CHG
4.9V 7.4V(2S) 

+

+

+

LiPo CHARGE
4.9A 7.4V(2S)

LiPo FAST CHARGE
4.9A 7.4V(2S)

LiPo STORAGE
4.9A 7.4V(2S)

+

LiPo DISCHARGE
2.2A 7.4V(2S)

  

ENTER

ENTER

[ BATT MEMORY 2 ]
 ENTER 

SET->

BATT TYPE
NiMH 

+

+

+

BATT VOLTAGE
 2.4V 

(2S)

CHARGE CURRENT
 3.3A

TRICKLE
 100mA

+

PEAK DELAY
 1Min

– +

[ BATT MEMORY 2 ]
C:1.0A D:1.0A

[ BATT MEMORY 2 ]
NiMH 2.4V 

(2S)

ENTER

+

SAVE PROGRAM
SAVE...

SAVE PROGRAM
 ENTER

DISCHG VOLTAGE
 1.1V/CELL

+

DISCHG CURRENT
 2.2A

+

ENTER CHARGER
LOAD...

NiMH CHARGE
CURRENT 1.0A 

+

v

+

NiMH Auto CHARGE
CURRENT 1.2A

NiMH DISCHARGE
1.0A CUT:2.0V

NiMH RE-PEAK
 

2

+

NiMH CYCLE
DCHG>CHG 1

ENTER

ENTER

[ BATT MEMORY 3 ]
 ENTER 

SET->

BATT TYPE
Pb 

+

+

+

BATT VOLTAGE
 4.0V 

(2P)

CHARGE CURRENT
 3.3A

DISCHG CURRENT
 1.5A

+

DISCHG VOLTAGE
 1.7V/CELL

– +

+

Pb NORMAL CHG
2.0A 2.0V 

(1P)

ENTER CHARGER
LOAD... 

ENTER > 3 Seconds

[ BATT MEMORY 3 ]
C:3.3A D:1.5A

[ BATT MEMORY 3 ]
 

Pb 4.0V (2S)

SAVE PROGRAM
SAVE...

ENTER

SAVE PROGRAM
 ENTER

INC

DEC

Pb AGM CHG
0.1A 2.0V 

(1P)

Pb COLD CHG
0.1A 2.0V 

(1P) 

PB DISCHARGE
0.1A 4.0V 

(2P)

Stop

Batt type

Load Factory Set
 Enter 

+

DC Input Low
Cut-off 1 

LOW 

NiCd Sensitivity
D.Peak 4mV

+

NiMH Sensitivity
D.Peak 4mV

BATT/PROGRAM

 BATT RESISTANCE

ENTER

BATT/PROGRAM

 BATT METER

ENTER

+

5 3 3 

5 0 0 

TOTAL: 16 mΩ

4.20 4.19 4.19V
0.00 0.00 0.00V

+

MAIN 12.58V
H4.20V L4.19V

– +

– +

Continued from page 7

Summary of Contents for ONXC4100

Page 1: ...ONXC4100 350 AC DC Balance Charger Discharger...

Page 2: ...ot properly followed create the probability of property damage collateral damage and serious injury OR create a high probability of superficial injury CAUTION Procedures which if not properly followed...

Page 3: ...process Always place the charger and the battery on a heat resistant inflammable and nonconductive surface Always keep all the inflammable volatile materials away from operating area Always keep the c...

Page 4: ...C 100 240V DC Input Resume or Start Charge Processes Confirm Any Action Temperature Sensor Ports Power Output Ports Balance Ports Alter Values See The Status Of Individual Cells In Balance Charge Mode...

Page 5: ...old 2 45V cell Balance Current 500mA cell Reading Voltage Range 0 1 26 1V cell Battery Types Cells LiPo LiHV LiFe LiIon 1 6cells NiMH NiCd 1 15cells Pb 2 20V Battery Capacity Range NiMH NiCd 100 50000...

Page 6: ...percentage Final voltage when the program ends Input voltage Safety timer and duration of time in minutes Cutoff temperature Internal and external temperature Temperature probe needs to be connected t...

Page 7: ...V 2S LiPo DISCHARGE 2 0A 7 4V 2S BATT PROGRAM LiFe BATT ENTER LiFe BALANCE CHG 2 0A 6 6V 2S LiFe CHARGE 2 0A 6 6V 2S LiFe FAST CHARGE 2 0A 6 6V 2S LiFe STORAGE 2 0A 6 6V 2S LiFe DISCHARGE 2 0A 6 6V 2S...

Page 8: ...ICKLE 100mA PEAK DELAY 1Min BATT MEMORY 2 C 1 0A D 1 0A BATT MEMORY 2 NiMH 2 4V 2S ENTER SAVE PROGRAM SAVE SAVE PROGRAM ENTER DISCHG VOLTAGE 1 1V CELL DISCHG CURRENT 2 2A ENTER CHARGER LOAD NiMH CHARG...

Page 9: ...ge modes by pressing the DEC or INC button Once finished press the BATT PROG STOP button to enter the BATT PROGRAM screen 1 Connection a Connecting to power source There are two kinds of power inputs...

Page 10: ...ber of cells of the battery pack before going ahead R shows the number of cells detected by the charger and S is the number of cells set by you at the previous screen If both numbers are identical pre...

Page 11: ...ndition of the battery connected to the output and automatically charges the battery CAUTION Never set the max charge current higher than 1C DISCHARGE This mode is for discharging NiMH NiCd battery RE...

Page 12: ...LiIon NiMH NiCd Pb Set the voltage and number of cells 1S 6S Set the charge current 0 1 12 0A Set the discharge current 0 1A 2 0A Set the discharge voltage 3 0 3 3V Cell Set the terminal voltage 4 18...

Page 13: ...tomatically stop the process at the selected capacity value Temp Cut Off On 50 C 122 F OFF ON 20 C 68 F 80 C 176 F The battery s internal chemical reaction will cause the temperature of the battery to...

Page 14: ...rrect polarity connected Current process has been interrupted Check all connections The battery connection is wrong or faulty The balance connect is wrong or faulty Input voltage is less than 11V Inpu...

Page 15: ...EEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES Further in no event shall the liability of Horizon exceed the individual price of the Product on which liability is asserted As Horizon has no control ov...

Page 16: ...s the expense exceeds 50 of the retail purchase cost By submitting the item for service you are agreeing to payment of the service without notification Service estimates are available upon request You...

Page 17: ...a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radi...

Page 18: ...18...

Page 19: ...19...

Page 20: ...2019 Horizon Hobby LLC Onyx IC3 and the Horizon Hobby Logo are registered trademarks of Horizon Hobby LLC Created 04 2019 60993...

Reviews: