5
ONXC4100
Net Weight
850g
Dimensions (L × W × H)
178 × 135 × 96mm
AC Power Input Voltage
100–240V
Display Type
2 × 16 LCD, Blue backlight
External Ports
1 6S Balance Socket-XH, Temperature Probe Socket,
Battery Socket, DC Input
Delta Peak Detection for
NiMH/NiCd
3-15mV/cell / Default: 4mV/cell
Battery Cutoff Temperature
20ºC/68ºF–80ºC/176ºF (adjustable)
Charge Voltage
NiMH/NiCd:
Delta peak detection
LiHV:
4.20–4.35V/cell
LiIon:
4.08–4.1V/cell
Pb AGM:
2.45V/cell
LiPo:
4.18–4.20V/cell
LiFe:
3.58–3.6V/cell
Pb Normal:
2.4V/cell
Pb Cold:
2.45V/cell
Balance Current
500mA/cell
Reading Voltage Range
0.1–26.1V/cell
Battery Types/Cells
LiPo/LiHV/LiFe/LiIon:
1–6cells
NiMH/NiCd:
1–15cells
Pb:
2–20V
Battery Capacity Range
NiMH/NiCd:
100–50000mAh,
LiPo/LiHV/LiFe/LiIon:
100–50000mAh,
Pb:
100–50000mAh
Charge Current
0.1A–12.0A
Safety Timer
1–120 minutes / OFF
Charge Wattage
100W × 2
Discharge Current
0.1A–2.0A
Discharge Cut-off Voltage
NiMH/NiCd:
0.1–1.1V/cell
LiHV:
3.1–3.4V/Cell
LiIon:
2.9–3.2V/cell
LiPo:
3.0–3.3V/cell
LiFe:
2.6–2.9V/cell
Pb:
1.8–2.0V/cell
Discharge Wattage
10W
Balance Cells
2–6 cells
Memory
10 different charge/discharge profi les
Charge Method
C/CV for lithium types and lead (Pb) batteries, Delta-peak Sensitivity for NiMH/NiCd
Specifi cations