Special Features

Dual Channel Charger

The Onyx

®

 350 allows you to charge 2 batteries with different 

chemistries simultaneously, and it will intelligently and 
automatically initiate the charging to their maximum capacity. 
Power of each channel is 100W.

Optimized Operating Software

The Onyx 350 features an AUTO function that automatically 
sets the current during charging/discharging. When charging 
lithium batteries, this may prevent overcharging, which may 
lead to a fi re. If the charger detects a malfunction, it will 
disconnect the circuit automatically and sound an alarm. 
Settings can be confi gured by the user.

Balance Voltage Calibration

The Onyx 350 allows you to calibrate the balance voltage 
with a 6S LiPo battery. (For more information please contact 
Horizon Product support)

Memory of Last Operation

The Onyx 350 will memorize your last operation of charging/
discharging before powering down.

AGM Charge and Cold Charge

For Pb batteries, there are two charging modes: AGM charge 
and Cold charge.

Battery Memory (Data Store/Load)

Store up to 10 different charge/discharge profi les for each 
channel. You can keep the data pertaining to program setting 
of the battery of continuous charging or discharging. Users 
can call out these data at any time without any special 
program setting.

Terminal Voltage Control(TVC)

Allows user to change the end voltage. (for expert user only)

Balancing Individual Cells Battery During Discharging

During the process of discharging, the Onyx 350 can 
monitor and balance each cell of the battery individually. 
An error message will be appear and the process will end 
automatically if the voltage of any single one cell is abnormal.

•  See the status of individual Lithium cells (works in any 

charge, discharge and storage modes)

• Capacity percentage 
•  Final voltage when the program ends
• Input voltage
•  Safety timer and duration of time in minutes 
• Cutoff temperature 

•  Internal and external temperature

(Temperature probe needs to be connected to show 
external temperature.)

•  Capacity cut-off and value of the set capacity limit

Fast Charge and Storage Mode of Lithium Battery

Fast charge mode shortens the overall charge time required 
for lithium batteries with a slight reduction in overall capacity. 
Storage mode is used for charging or discharging lithium 
batteries that will not be used for an extended period of time.

Re-Peak Mode of NiMH/NiCd Battery

In re-peak charge mode, the charger can peak charge the 
battery once, twice or three times in a row automatically. This 
is good for making sure the battery is fully charged.

Cyclic Charging/Discharging

A series of 1 to 5 charge to discharge (>) or discharge to 
charge cycles can be used for refreshing older batteries and 
improve cell balance.

Automatic Charging Current Limit

Set the upper limit of the charging current when charging 
your NiMH or NiCd battery, battery. This is useful for NiMH 
batteries with low impedance and capacity in the ‘AUTO’ 
charging mode.

Battery Voltage Meter

Check battery’s total voltage, the highest voltage, the lowest 
voltage and each cell’s voltage.

Battery Internal Resistance Meter

Check battery voltage and battery internal resistance.

Capacity Limit

The charging capacity is always calculated as the charging 
current multiplied by time. If the charging capacity exceeds 
the limit, the process will be terminated automatically when 
you reach the set maximum value.

Temperature Threshold

The battery’s internal chemical reaction will cause the 
temperature of the battery to rise. If the temperature limit 
is reached, the process will be terminated. This function is 
only available by connecting the optional temperature probe 
(DYN5033).

Processing Time Limit

You can limit the maximum process time to avoid 
overcharging the battery. 

Summary of Contents for ONXC4100

Page 1: ...ONXC4100 350 AC DC Balance Charger Discharger...

Page 2: ...ot properly followed create the probability of property damage collateral damage and serious injury OR create a high probability of superficial injury CAUTION Procedures which if not properly followed...

Page 3: ...process Always place the charger and the battery on a heat resistant inflammable and nonconductive surface Always keep all the inflammable volatile materials away from operating area Always keep the c...

Page 4: ...C 100 240V DC Input Resume or Start Charge Processes Confirm Any Action Temperature Sensor Ports Power Output Ports Balance Ports Alter Values See The Status Of Individual Cells In Balance Charge Mode...

Page 5: ...old 2 45V cell Balance Current 500mA cell Reading Voltage Range 0 1 26 1V cell Battery Types Cells LiPo LiHV LiFe LiIon 1 6cells NiMH NiCd 1 15cells Pb 2 20V Battery Capacity Range NiMH NiCd 100 50000...

Page 6: ...percentage Final voltage when the program ends Input voltage Safety timer and duration of time in minutes Cutoff temperature Internal and external temperature Temperature probe needs to be connected t...

Page 7: ...V 2S LiPo DISCHARGE 2 0A 7 4V 2S BATT PROGRAM LiFe BATT ENTER LiFe BALANCE CHG 2 0A 6 6V 2S LiFe CHARGE 2 0A 6 6V 2S LiFe FAST CHARGE 2 0A 6 6V 2S LiFe STORAGE 2 0A 6 6V 2S LiFe DISCHARGE 2 0A 6 6V 2S...

Page 8: ...ICKLE 100mA PEAK DELAY 1Min BATT MEMORY 2 C 1 0A D 1 0A BATT MEMORY 2 NiMH 2 4V 2S ENTER SAVE PROGRAM SAVE SAVE PROGRAM ENTER DISCHG VOLTAGE 1 1V CELL DISCHG CURRENT 2 2A ENTER CHARGER LOAD NiMH CHARG...

Page 9: ...ge modes by pressing the DEC or INC button Once finished press the BATT PROG STOP button to enter the BATT PROGRAM screen 1 Connection a Connecting to power source There are two kinds of power inputs...

Page 10: ...ber of cells of the battery pack before going ahead R shows the number of cells detected by the charger and S is the number of cells set by you at the previous screen If both numbers are identical pre...

Page 11: ...ndition of the battery connected to the output and automatically charges the battery CAUTION Never set the max charge current higher than 1C DISCHARGE This mode is for discharging NiMH NiCd battery RE...

Page 12: ...LiIon NiMH NiCd Pb Set the voltage and number of cells 1S 6S Set the charge current 0 1 12 0A Set the discharge current 0 1A 2 0A Set the discharge voltage 3 0 3 3V Cell Set the terminal voltage 4 18...

Page 13: ...tomatically stop the process at the selected capacity value Temp Cut Off On 50 C 122 F OFF ON 20 C 68 F 80 C 176 F The battery s internal chemical reaction will cause the temperature of the battery to...

Page 14: ...rrect polarity connected Current process has been interrupted Check all connections The battery connection is wrong or faulty The balance connect is wrong or faulty Input voltage is less than 11V Inpu...

Page 15: ...EEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES Further in no event shall the liability of Horizon exceed the individual price of the Product on which liability is asserted As Horizon has no control ov...

Page 16: ...s the expense exceeds 50 of the retail purchase cost By submitting the item for service you are agreeing to payment of the service without notification Service estimates are available upon request You...

Page 17: ...a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radi...

Page 18: ...18...

Page 19: ...19...

Page 20: ...2019 Horizon Hobby LLC Onyx IC3 and the Horizon Hobby Logo are registered trademarks of Horizon Hobby LLC Created 04 2019 60993...

Reviews: