SHENZHEN ONTIME TECHNOLOGY CO.LTD
20
motor.
This parameter defines the upward speed of torch lifting
motor during initial height setup procedure.
Range: MIN_PWM-MAX_PWM
,
default
:
30.
IhsDN PWM
:
The IHS downward PWM value of the lifting
motor.
This parameter defines the downward speed of torch
lifting motor during initial height setup procedure.
Range: MIN_PWM-MAX_PWM
,
default
:
90.
U&D_ PWM
:
The upward and downward PWM value of the
lifting
motor.
This parameter defines the speed of torch lifting motor
during manual torch height control.
Range: MIN_PWM-MAX_PWM
,
default
:
120.
ARC_TOLE
:
Arc voltage toleration range.
This parameter defines the maximum allowable positive
deviation from the given arc voltage. An arc voltage
deviation bigger than this value means that the torch is
cutting across a kerf, and the controller will disable
auto height control temporally to avoid the cutting torch
diving into the workpiece.
Summary of Contents for AVC118