4705-820 Braga Portugal                                                                                                                                             [email protected]                                                                                                                                                                                                            
Tel: +351 253 221 484                                                                                                                                                 www.only-smartbuildings.com 

 

OPERATION 

 

OTC-CLIMA 

 

When the OTC-CLIMA is switched off, touching the panel will only light up the LED 
of the   key. This means that the only possible operation is switching the unit on or 
off. 
 
To switch on the unit press  : you will hear two beeps indicating that the unit is on 
and the LEDs of some other keys light up. 

 

Manual operation 
The OTC-CLIMA can operate in automatic and manual mode. To operate in 
automatic mode it is necessary that the unit has the date and time adjusted. If this is 
not the case, the unit can only function in manual mode. 
If the display shows only the temperature, this means that there is no date and time 
adjusted. 
In this case, when you switch on the unit with the   key, it automatically goes to 
manual mode. This is indicated by the LED of the   key that blinks or lights up. 

 blinks  - unit switched on but climatization switched off 
 lights up 

- unit switched on and climatization switched on 

In this last case the LCD indicates 

 if it is cooling or 

 if it is heating up. 

During manual operation the ideal temperature is the one that is previously adjusted 
for the respective season. 
If desired, you can edit the target temperature by pressing the keys   to increase or 

 to decrease. 

 

Automatic operation 

 

If the date and time are adjusted, the display shows the time. In this case, when you 
switch on the unit it goes to automatic mode.  
If the actual time is outside of any defined operating period the unit stays in 
STANDY, waiting for an operating period to start. 
In this case the   key does not light up, indicating that the climatization is switched 
off. 
Pressing the   key switches the unit on in manual mode. The target temperature is 
the defined ideal temperature. Climatization is switched on if necessary.  
As an alternative, you can press   in winter or   in summer. In this case 
climatization is always switched on being the target temperature the actual 
temperature plus (winter) or minus (summer) 1º. 
When the time reaches an operating period, the defined target temperature of that 
period is selected and the unit switches to automatic mode.  
When the program ends, climatization is switched off.  
 
To switch off the unit, press   for more than 1 second. 
 
 
 
 

1234567 

                23º 

    1234567 

                23º 

     1234567 

 10:12      23º 

1234567 

                23º 

Summary of Contents for Climatization

Page 1: ...Climatization User Manual ...

Page 2: ...nd time 4 2 Setting the cycle 5 3 Winter programme 5 4 Summer programme 6 5 Installation of OTC TERMO 7 6 Removing an OTC TERMO 7 Ideal temperatures OTC CLIMA 8 Ideal summer temperature 8 Ideal winter temperature 8 CONFIGURATION OF THE OTC TERMO 8 Ideal temperatures 8 Ideal winter temperature 9 Ideal summer temperature 9 Selection of Winter and Summer cycle 9 OPERATION 10 OTC CLIMA 10 Automatic op...

Page 3: ...n and comfort is a priority for ONLY the operation is done via touch panels of the ONLY TOUCH line in total harmony with the rest of the commands in the house EQUIPMENT In your house you will probably find two types of climate control units one with an LCD display OTC CLIMA one or various without LCD OTC TERMO Both are programmable thermostats that can manage independently the temperature of the r...

Page 4: ...option and the button lets you exit the current menu and go back to the former 1 Setting the date and time The ONLY climate control units have illuminated touch sensors that function as buttons They allow the following functions To set the date and time press within the option 1 DATE With the keys and you select the digit you want To move to the next digit press or press to go to the previous digi...

Page 5: ... where the higher temperature prevails The starting time of a period has to be before the end time Period 1 does not have to start before period 2 or 3 To adjust the winter programme press within the option 3 WINTER The option LOCAL allows you to define the programme on the local unit If there are OTC TERMO s installed you can choose here which unit you wish to programme using the and keys and val...

Page 6: ...the local unit If there are OTC TERMO s installed you can choose here which unit you wish to programme using the and keys and validating with the key You can now select the day of the week you wish to edit with the and keys Going to the right you can select all days of the week only Monday to Friday or only the Weekend In this case of multiple days of the week you cannot edit the programme that wa...

Page 7: ...n is finished press to leave the menu To set the programme for the OTC TERMO units you should select the respective number e g T01 with and and validate it with The definition of the programme is now exactly the same as the local unit except that the programme is afterwards stored in the respective unit Note If a name was assigned to the OTC TERMO only possible with a computer this name will appea...

Page 8: ...ely the PROG key Once the desired value is selected you can confirm it with Ideal winter temperature Adjustment of the winter temperature is done by pressing PROG for 2 seconds when touching the panel only the keys and light up Press the key to adjust the winter temperature On the LCD you will see the selected temperature You can select between 18º and 29º pressing successively the PROG key Once t...

Page 9: ...Keep de key PROG pressed during 2 seconds Press the button The LED of the temperature scale light up indicating the actually selected temperature Press PROG to select the next temperature Pressing PROG repeatedly increases the temperature until the turnaround point and return to the lowest temperature You can select a temperature from 20ºC until 25ºC in 1ºC steps Confirm the selection by pressing ...

Page 10: ...t case the LCD indicates if it is cooling or if it is heating up During manual operation the ideal temperature is the one that is previously adjusted for the respective season If desired you can edit the target temperature by pressing the keys to increase or to decrease Automatic operation If the date and time are adjusted the display shows the time In this case when you switch on the unit it goes...

Page 11: ... directly to manual mode This is indicated by the LED of the key that lights up or starts blinking blinking unit switched on but climatization switched off lights up unit and climatization switched on During manual functioning the ideal temperature is the one previously adjusted for the respective season If desired you can change the target temperature by pressing the keys to increase or to decrea...

Page 12: ... are commands that allow the combination of different states of multiple outputs The climatization units can be linked to these scenarios like the other units For the scenario the status of the unit is memorized switched off automatic mode manual mode The unit will enter the respective mode when the SCENARIO command is received Association with ON or OFF The commands ON and OFF are commands that d...

Page 13: ...o be configured according to the installation in which they are used This configuration should be done by the installer because it depends on the installation architecture and the physical connections made Therefore you should never reset to the factory default settings because the unit will no longer function To reset the unit to the factory default press PROG for more than 10 seconds At the end ...

Reviews: