KEYPAD OVERVIEW 

 

             

Navigation buttons inside menus. 

 

  Back 

  Up 

  Down 

  Next/Enter 

 

 

Menu button for language selection, display brightness change 
and software versions visualization. 
 

 

 

 

Buttons to select the Arming mode 

-

 

 

Total, 

 

Night 

e

  

 

Partial - 

 pressed just after typing in the user code. 

Arming in total mode does not requires to press the respective 
button after the code.  
 
Button 

  is  also  used  to  configure  the  scenario  activated 

automatically when exit times finishes (e.g., switch-off lights, 
move rolling shutters down, etc.). 
Button 

  can  be  used  to  activate  a  scenario  like  “arriving 

home in the evening”. 
Button 

 sends a message ON/UP to the automation BUS that 

can be used to switch on lights, move blinds or roller shutters 
up or others.  
 

0..9 

Numeric buttons to introduce user, master or service code.  
 

 

Button DOWN that can be used to configure a general 
command blinds or roller shutters down. 
 

 

Button OFF that can be used to configure a general command 

to switch off all the lights. 

Summary of Contents for C-4ZON-D-RF

Page 1: ...SECURITY SYSTEM User Manual ...

Page 2: ...SECURITY History Version Date Changes 2 0 2017 03 08 ...

Page 3: ...e presence simulator on off 16 Switching on off Confirmed Alarm 16 Programming phone numbers 17 Defining Time and Date 17 Changing the master code 18 Exit the master menu 18 SYSTEM OPERATION 19 Arm and disarm the alarm 19 Night mode 19 Partial mode 20 Restore Water supply 20 Restore Gas supply 20 Presence simulator 21 Confirmed alarm 22 Adding remote controls 22 Removing remote controls 22 Adding ...

Page 4: ...URITY Command Partial 27 Command Close blinds 27 Command Switch off lights 27 Programming of actions in case of alarm 28 Language selection 29 Adjusting the OLED display brightness 29 Software versions 29 ...

Page 5: ...o dissuade the intruder1 Button for personnel emergency telephone call Two way communication through telephone with voice messages Control by phone of gas and water valves Control by phone of lights blinds air conditioning and other functions1 Technical alarms 1 When installed with ONLY automation This manual explains the features and how to use the system from the standpoint of the user INTRUSION...

Page 6: ...d during the night when people are at home and sleeping It s for example the magnetic contacts or even volumetric detectors of other zones of the house not visited during the night Partial zones are all those that must be protected even when there are people at home They are for example volumetric detectors in garages or other outbuildings that usually are not visited by people in the house during...

Page 7: ...h domotics The C 4ZON D RF is a 4 zone expansion unit It is intended to connect up to 4 zone detectors and communicates with the central through the security bus Up to 8 expansion units can be used in the system totalling up to 40 different zones It is equipped with a RF receiver The OT 16SD is a security keyboard with OLED that allows users to interface with the system Through them it is possible...

Page 8: ... ONLY automation system the user can choose arming the alarm with or without simulation of people at home When activated the security central repeats the moves of the users made in the house the day before simulating the occupation Obviously only the buttons defined by the user will be stored so that not all the circuits of the house are used When power fails it is impossible to open a motorized s...

Page 9: ...gas valve immediately closed water valve immediately open and water detection is disabled Gas gas valve immediately closed telephone numbers dialled with message gas leakage detection Water water valve immediately closed telephone numbers dialled with message water leakage detection Panic call to 24 hour central and to telephone number memorized on position 6 with message Personal emergency The se...

Page 10: ... to all telephone numbers message Intrusion detection Partial Mode call to all telephone numbers message Intrusion detection This routine lasts for a period of alarm time defined by the installer with a minimum of 3 minutes If nobody switches the alarm off enter a valid code or pressing the disarm button on the remote control during this time the alarm will repeat the routine but this time with ac...

Page 11: ... Smoke Fire alarm indication red ALARM E Indication LEDs 1 to 8 F Status indication green disarm red arm total orange arm night G Tamper indication red Tamper H Fault indication red fault detected I Expansion unit indication red triggered J Total alarm scenario key K Night alarm scenario key L Add key to add expansion units or RF remotes M OK key to acknowledge situations The LEDs 1 to 8 inform di...

Page 12: ... the following indications When the alarm was caused on a local zone the STATUS LED blinks and the respective zone LED is ON When the alarm was caused on an expansion zone the EXPANSION LED blinks and the respective unit number is shown on LEDs 1 to 8 On the keyboard in case of an alarm the icon is shown on the display simultaneously the internal beeper of the keypad sounds The user will have to d...

Page 13: ...to configure the scenario activated automatically when exit times finishes e g switch off lights move rolling shutters down etc Button can be used to activate a scenario like arriving home in the evening Button sends a message ON UP to the automation BUS that can be used to switch on lights move blinds or roller shutters up or others 0 9 Numeric buttons to introduce user master or service code But...

Page 14: ...80 Important note After installing the security system factory codes must be modified MASTER MENU The master menu allows the responsible for the installation to define the following parameters add and delete user codes define the duress code turn on or off the automatic night arming turn on or off the confirmed alarm turn on or off the simulator of people at home change phone numbers define date a...

Page 15: ...t and enter the code once more to confirm A confirmation beep is played if both entries are equal and the message Code accepted is shown If the entered code is not the same or if the used digits are of an already existing code then the user is prompted to repeat the process of a new code creation Deleting user codes To delete a user code one by one select Users press key select Delete one by one p...

Page 16: ...n Switching on off the Automatic arming at night Your installer can set the night period usually between 00 00 and 06 00 To activate the function automatic arming at night select the option Automatic arming press key the activation is signalized with To deactivate this function select Automatic arming and press again Switching the presence simulator on off To activate the function presence simulat...

Page 17: ...r till the last digit using key and press key to delete the number digit by digit When the number is totally deleted press key the message Phone stored is displayed to confirm the deletion Defining Time and Date If the date and time is not defined it is not possible to register events required to be able to verify what happened behind When arming the alarm without having defined date and time you ...

Page 18: ...key and enter the 6 digit code Repeat the code to confirm it If correct a confirmation beep will sound and the message Code Accepted is shown If the entered code is not the same you will need to re enter the code until it is valid Exit the master menu To exit the master menu at any point press key ...

Page 19: ...ogrammable by the OLED keypad or by the PC application Night mode The night mode allows protection of the house arming only the peripheral and partial zones allowing the circulation inside the house If the function Automatic Night Arm is enabled you don t need any action the alarm will arm during the defined night period or after you go to bed The night period is definable by the PC application or...

Page 20: ...supply The water cut relay is activated when water leakage is detected for more than 30 seconds This time is necessary to prevent the water supply to be cut when for example cleaning the floor To restore water supply you must either restore it with a phone call see Command through telephone or enter the Master Code Restore Gas supply The gas cut relay is activated automatically when a gas leakage ...

Page 21: ...s the buttons you want the system to store Note you can add buttons controlling lights shutters dimmers and sound devices on off button only When you finish press the again on the security central From now on the system will record everyday the manoeuvres made on those buttons storing the time that each of them was made When the system is armed in total mode and the simulator is switched on the ce...

Page 22: ...lid user code on the keypad you will hear a confirmation beep Press now one of the keys on the remote control the state LED F of the central switches to green and the remote control is installed From now on the upper right button arms the alarm the upper left button disarms it and the bigger round button causes a personal emergency call when pressed for more than 5 seconds Removing remote controls...

Page 23: ...he expansion unit select the Install C4ZON option press the message Done is shown The unit is installed in the selected position replacing any unit that was eventually installed on that position To exit press repeatedly the key L until the Power LED A or State LED E become green Removing expansion units The expansion units can be removed from the central if they are no longer needed For this proce...

Page 24: ...ion keys or the identification of the installation Important In case you typed in a wrong digit just wait 3 seconds and restart entering your code If 2 wrong codes are entered the system will hang up You can make a second call and try again 2 times After that the system will not answer external calls for at least 15 minutes Functions with user code After a valid user code is received the telephone...

Page 25: ...the event message To record a new identification message proceed as follows Press 0 the identification message is played over and over again Press to start recording speak your message into the telephone After 6 seconds the recorded message is played back over and over again If you wish you can record the message again by pressing to start over To record a message for keys 5 to 8 proceed as follow...

Page 26: ...d on The commands switch off down or switch on up are commands that define a specific state of the outputs they control The outputs actuated by these buttons can be programmed in the same way as all buttons of the automation system Press the PROG key on the modules controlling the outputs you wish to command and select the outputs you wish to associate to the desired button Then press the button t...

Page 27: ...g a user code In this case it allows the selection of arming the Partial mode Command Close blinds The key sends the command Switch Off Down when being pressed regardless of the security keypad on which it is pressed It is intended to centralize the closing of all the blinds in the house Command Switch off lights The key sends the command Switch Off Down when being pressed regardless of the securi...

Page 28: ... the user 3 The system is disarmed by telephone In this case the system sends the command Close Switch off which will turn off the lights and close the blinds associated to the scenario Note that pressing to arm the system causes the sending of the scenario Leaving Home which is the same as pushing the key on a security keypad In case of an alarm in the night or partial mode since it allows users ...

Page 29: ...key to access Menu select Brightness and press You can adjust the desired maximum and minimum levels The maximum level refers to the brightness that the OLED display has when we are handling the keyboard on the other hand the minimum level refers to the level that the OLED display has in steady state Select Maximum or Minimum and use the key to increase or decrease the respective brightness Select...

Reviews: