FR-155
22
17
18
20
19
MD MECHANISM DISASSEMBLY
Remove the screw(51) used to fix the guide shaft(61).
Lead holder B(72)
Screw(51)
Guide shaft (61)
Remove the pick-up unit(74).
Pick-up unit(74)
MD MECHANISM REASSEMBLY
1. To reassemble each mechanism, reverse the applicable disassembling procedure.
2. Do not do unsoldering short land on the pick-up unit before connecting the flexible flat cables.
3. When motor plate ass'y is installed in the MD mechanism, it is necessary to note the position of the gear.
Loosen the screw(51) used to fix the guide shaft (61).
Lead holder A(71)
Screw(51)
Pick-up unit(74) is exchanged.
And it is necessary to place the push switch on L-SW prited circuit board (3) and note not getting crowded.