FR-155
SPECIFICATIONS
2
General
Power supply
AC 220-230 V, 50/60 Hz
AC 120 V, 60 Hz
Power consumption
63 W (220-230 V, 50/60 Hz)
82 W (120 V, 60 Hz)
(Standby)
7 W
(Energy Save)
1.5 W
Clock precision
monthly error:
30 seconds
(at 25 degrees Celsius)
Dimensions (W
×
H
×
D)
205
×
154
×
356 mm
8-1/16"
×
6-1/16"
×
14"
Weight
5.5 kg, 12.1 lbs
Amplifier
Power output
2
×
26 W at 4 W EIAJ
2
×
21 W at 6 W EIAJ
Rated Power
2
×
19 W min, RMS at 4 W
1 kHz no more than
0.2 % THD
Dynamic power
2
×
23 W at 4 W
Total harmonic distortion
0.4 % at rated power
IM distortion
0.2 % at rated power
Damping factor
25 at 8
Ω
Sensitivity and impedance
LINE, TAPE:
150 mV, 50 kW
CDR: 150 mV, 50 kW
Frequency response
10 to 50,000 Hz : +0dB / -3 dB
Tone Control
S.BASS1: +4 dB at 40 Hz
S.BASS2: +8 dB at 50 Hz
S.BASS3: +4 dB at 10 kHz/
+8 dB at 50 Hz
Signal to noise ratio
LINE, CDR, TAPE: 100dB
(IHF-A)
Muting
50 dB
CD player
Signal readout system
Optical non-contact
Frequency response
10 Hz to 20 kHz ( 3 dB)
Wow and flutter
Below threshold of
measurability
MD recorder
Signal readout system
Optical non-contact
Recording time
320 minutes maximum
(at LP4 mode)
Frequency response
10 Hz to 20 kHz ( 3 dB)
Wow and flutter
Below threshold of
measurability
Tuner
Tuning range
FM: 87.50 to 108.00 MHz
(50 kHz steps)
AM: 522 to 1611 kHz
(9 kHz steps)
Usable sensitivity
FM Mono:11.2 dBf,
1.0
µ
V (75 W IHF)
Stereo:17.2 dBf,
2.0
µ
V (75 W IHF)
AM: 30
µ
V
50 dB quieting sensitivity
FM Mono:17.2 dBf,
2.0
µ
V (75 W)
Stereo:37.2 dBf,
20.0
µ
V (75 W)
Capture ratio
2.0 dB
Image rejection ratio
FM: 85 dB
AM: 40 dB
IF rejection ratio
FM: 90 dB
AM: 40 dB
Signal to noise ratio
FM Mono : 73 dB IHF
Stereo : 67 dB IHF
AM: 40 dB
Selectivity
FM: 50 dB
( 300 kHz at 40 kHz devi.)
Harmonic distortion
FM: Mono: 0.7 %
Stereo: 0.3 %
AM: 0.7 %
Frequency response
FM: 30 to 15,000 Hz ( 1.5 dB)
Stereo separation
FM: 40 dB at 1,000 Hz
FM: 30 dB at 100 to 10,000 Hz
Specifications and features are subject to change without noitce.
CAUTION ON REPLACEMENT OF OPTICAL PICKUP
The laser diode in the optical pickup block is so sensitive to
static electricity, surge current and etc., that the components
are liable to be broken down or its reliability remarkably
deteriorated.
During repair,carefully take the following precautions.
(The following precautions are included in the service
parts.)
PRECAUTIONS
1.Ground for the work-desk.
Place a conductive sheet such as a sheet of copper
(with impedance lower than 10 Mohm) on the work-
desk and place the set on the conductive sheet so that
the chassis can be grounded.
2.Grounding for the test equipments and tools.
Test equipments and toolings should be grounded in
order that their ground level is the same the ground of
the power source.
3. Grounding for the human body.
Be sure to put on a wrist-strap for grounding whose
other end is grounded.
Be particularly careful when the workers wear
synthetic fiber clothes, or air is dry.
4. Select a soldering iron that permits no leakage and
have the tip of the iron well-grounded.
5. Do not check the laser diode terminals with the