C-1VL
SERVICE PROCEDURES-2
04 330A
--->
00 00:00
1. Replacing the fuse
This symbol located near the fuse indicates that the
fuse used is show operating type, For continued protection against
fire hazard, replace with same type fuse , For fuse rating, refer to
the marking adjacent to the symbol.
Ce symbole indique que le fusible utilise est e lent.
Pour une protection permanente, n'utiliser que des fusibles de meme
type. Ce demier est indique la qu le present symbol est apposre.
REF. NO.
F991
PART NAME
FUSE
DESCRIPTION
0.315A-SE-EAWKFUSE
PART NO. (SN)
252082
!
: OFF
: OFF
DIGITAL OUTPUT button
POWER button
2. Setting position before shipment
3. Check the version of microprocessor
(1) Connect the AC power cord into a wall outlet.
(2) Press
POWER
button to turn on the unit.
(3) Change into the state of
"NO DISC"
.
(4) Press and hold down the
STOP [ ]
button, then press the
FF (fast forward) [ ]
button.
(5) Press
POWER
button to turn off the unit.
(6) Disconnect the AC power cord from a wall outlet.
version
1 second
FL display