INSTALLATION
Step4. Install the frame.
1. Install the frame and connect the coupler plugs, making sure not to interfere with the
temperature sensor cable (See Fig.9).
2. Fix the screws on the frame (See Fig.3).
Step 5. Install the air filter and front panel.
1. Install the air filter into the frame’s slot from upside to underside (See Fig.2).
2. Hang the front panel on the frame’s buckle, then press the front panel into the frame’s slot
until you hear a click (See Fig.10).
ELECTRICAL
REQUIREMENTS
Electrical requirements
•
Wiring up to the location of the air conditioner should be as under :
- 7/20 gauge
•
The MCB for the air conditioner should not be rated less than 20 Amps.
•
The meter to which your air conditioner line is connected, should have at least a
20 Amp. rating
•
Wire ends should be tightened fully.
•
Your air conditioner operates at a voltage of 230 V AC ± 10%. In case your area
experiences voltage fluctuation please use a suitable voltage stabiliser, as per the
table below :
Model Tonnage of your Voltage Stabilizer
Air conditioner
Rating
W12TRC3 / W12TRC2 1.0 Ton
3 KVA
W18TRC3 / W18TRC2 1.5 Ton
4 KVA