background image

13

12

GENERAL INSTRUCTIONS FOR 

INSTALLATION

Locating the Outdoor Unit

The  outdoor  unit  houses  the  compressor, 
condenser  fan  and  electrical  components. 
The heat removed from the room is expelled 
to the atmosphere through the outdoor unit.

Once again, the Onida / dealer's Technician 
will ensure optimal installation of the ODU for 
you. However, the following information will 
be of interest to you.

• The Outdoor Unit can be mounted on a 

wall, sunshade or skirting.

• Ideally,  the  ODU  should  not  be  too 

far  a w a y   f r o m   t h e   I D U ;   t h e  
recommended 

distances  are 

marked in 

the adjacent figure.

• Ensure that air can pass freely through 
the 

unit. Please allow at least 2 meters 

free 

space on the air outlet side, and 0.3 

meters on the air inlet side.

• If more than one ODU is to be installed, 

they must be properly separated, so that 
the warm air from the outlet of one does 
not enter the inlet of the other.

• Avoid long and complicated routing 

between  the  IDU  and  ODU,  as 
shown in the three adjacent figures.

• Too long

• Too high

• Too many bends

• The ODU must be placed on strong 

frame  or  support.  If  mounted  on  a 
wall, please ensure that the wall is 
thick enough and that the frame is 
supported adequately.

• Finally,  it  is  most  important  for  the 

ODU to be easily accessible to the 
service  engineer.  It  is  advisable  to 
discuss the same with the engineer 
before deciding upon the location of 
the unit.
If the ODU is to be located on a high 
ledge,  adequate  space  must  be 
provided for the service engineer to 
service the unit. It is a good idea to 
provide  a  catwalk  (a  platform) 
around  the unit and  access  door  / 
window to the Unit.

Electrical outlet

After the location of the outdoor unit and 
indoor unit is finalised, you must provide 
a  suitable  electrical  outlet  near  the 
indoor unit.

GENERAL INSTRUCTIONS FOR 

INSTALLATION

MCB

To ODU

STABILISER

To ODU

Summary of Contents for S09CFL-G3

Page 1: ... you better by registering your product for Warranty Web Registered at w Telephone Post Visit Post the Warranty Registration Card ww onida com Call Centre No 0XX 39889000 0XX STD Code of State Capital Service Centre Copy or Visit the Nearest Service Centre Model S09CFL G3 S12CFL G3 S18CFL G3 Model S12GLS N4 S18GLS N4 cool cool 3 STAR 2 STAR ...

Page 2: ...ntinuous improvement through innovation and human development to give customer better value for money always ONIDA stands committed to provide the ultimate customer satisfaction as nothing brings us greater joy than having satisfied customers of ONIDA At ONIDA feedback and suggestions based on your product usage experience is greatly appreciated Please contact to us at response onida com G Sundar ...

Page 3: ...tions for Installation 11 Installation Sketch 14 Installation of Model 15 Take care of your Air Conditioner 18 Precautions to be taken 19 Trouble Shooting 21 Installation and Satisfaction Report 23 Warranty Terms Conditions 25 Preventive Maintenance Service Coupon 27 Warranty Card Customer Copy 29 Warranty Card service Centre Copy 31 List of service centre no s in India 33 ...

Page 4: ...rmance a Imported High BTU Compressor b Trapezoidal Inner Grooved Tube c Large L Shaped Condenser Coil d High Technology 3 Star 2 Star Energy Efficient Features a Vertical Swing b Turbo c i Cool d Auto Restart Safety Reliability a Gold Fins b Full Function LCD Remote c 5 Stage Epoxy Polyester Painting d Rugged Construction With Thicker Gauge Steel S12GLS N4 S18GLS N4 3 STAR ...

Page 5: ...IEW COLOR FLAT GOLD n OUTDOOR UNIT Air in Exhaust Air Connection pipe and connecting wire n OUTDOOR UNIT Air in Exhaust Air Connection pipe and connecting wire n INDOOR UNIT n INDOOR UNIT n INDOOR UNIT n INDOOR UNIT Conditioned Air Out Conditioned Air Out Return Warm Air In Return Warm Air In Remote Controller Remote Controller Front Panel Front Panel Display Display ...

Page 6: ...pen back cover and put 2 Nos AAA size alkaline batteries 2 Short one RESET piece after changing the batteries 3 The remote signal can be reached up to six meters from the indoor unit 4 When the button is pressed on remote indoor unit will beep once indicating the receipt of signal If no beep sound is heard press the button once again 5 Remove batteries if remote control has not been used for long ...

Page 7: ...O mode is selected 2 symbol can be seen on the Remote panel when you select the AUTO mode 3 In this mode the fan speed can be changeable 0 4 Temperature can be pre set in this mode default temperature is 25 C 5 In the AUTO mode your AIR CONDITIONER Thinks for you The unit automatically and continuously monitors the difference between room temp and set temp and adjusts the fan speed accordingly to ...

Page 8: ...peration To switch on Sleep operation Press SLEEP button once on remote Remote display will shows the symbol After setting sleep mode 5 seconds after display will be goes off In this mode Fan speed will be in Low Speed only After selection of SLEEP Mode if you press fan speed button fan speed will change as per the selection unless it will be in low speed only O In cool mode after Sleep mode is se...

Page 9: ... as shown in the figure GENERAL INSTRUCTIONS FOR INSTALLATION Locating the indoor and outdoor units properly will help optimise the performance of your airconditioner While your Onida Dealer s Technician will be happy to guide you on the best location for your airconditioner here are a few helpful hints Locating the Indoor Unit Locate the IDU for the best cool air circulation Preferably there shou...

Page 10: ...d so that the warm air from the outlet of one does not enter the inlet of the other Avoid long and complicated routing between the IDU and ODU as shown in the three adjacent figures Too long Too high Too many bends The ODU must be placed on strong frame or support If mounted on a wall please ensure that the wall is thick enough and that the frame is supported adequately Finally it is most importan...

Page 11: ...Connecting of cables 1 Open the front panel 2 Dismantle the electric box cover and fastener 3 Connect the cable 4 Reassemble the fastener and electric box cover 150mm or more to ceiling Indoor unit outline Installation plate 293 Right rear side refrigerant pipe hole 65 Left rear side refrigerant pipe hole 65 120mm or more to wall 120mm or more to wall 995 45 90 45 45 Blue Terminal board Power conn...

Page 12: ...the closing valve with Allen wrench turn 90 clockwise then push the gas hole for about 10 seconds When a gas like fog appears it indicates that the air of unit has been discharged put back the screw cap of gas charging hole Do the leak test with leak detector or soap water n Add refrigerant If the connecting pipe is longer than 7 meters add refrigerant as needed Add amount A Lm 7m 15g m A add refr...

Page 13: ...tap until they are clean Do not use detergents for cleaning the filter PRECAUTIONS TO BE TAKEN Do s Seal all air gaps in the room Choose the right temperature to avoid over cooling Ventilate the room regularly Switch off the power supply if not in use for long Unplug the unit while cleaning Don t s Don t leave the doors and windows open when the air conditioner is on Don t use hot water to clean y...

Page 14: ... or the remote Remove all obstructions to make the airflow paths free Change to COOL mode Make the selected temperature less than room temerature Clean the air filter MCB has tripped Fuse has burnt Input voltage to the stabiliser is below acceptable range The On Off key is not pressed The airflow paths are not free The Units is in the fan mode Selected temperature is more than room temperature Air...

Page 15: ... Grill Temp C Input Voltage Remote Operation Customer s Response To be filled up by the Customer 1 Installation completed within 12hrs 24 hrs 36 hrs more than 36 hrs 2 How did you find the behavior of the Engineer Excellent J Good K Not satisfied L 3 Overall rating of the service Excellent J Good K Not satisfied L 4 Suggestion if any Job Number Engineer s Signature Customer s Signature INSTALLATIO...

Page 16: ...der the terms of this warranty are warranted only for the remaining period of the original warranty period 5 For attending any service call under this warranty beyond the municipal limits of the locality in which the authorized representative dealer is situated outstation locations all to and fro travelling and other incidental expenses as prevailing from time to time incurred in connection with t...

Page 17: ...y the terms and conditions of this warranty 14 This warranty shall be deemed to have been issued at Mumbai state of Maharashtra and courts at Mumbai shall have exclusive jurisdiction on matters covered by or following from this warranty and the original purchaser alone shall have cause of action arising out of the transaction Preventive Maintenance Service 1 Date ________ Customer Identification N...

Page 18: ... that it will perform as per your expectations We thank you for taking your time to complete this form All Information Provided by You will be Kept Confidential Please Fill In Tear off Fold and Mail this form to Reach us within 10 days of the Product Purchase We welcome your Valuable Suggestions if any to Improve our Products and Services FOR OFFICE USE ONLY Customer Code MIRC Electronics Limited ...

Page 19: ...l In Tear off Fold and Mail this form to Reach us within 10 days of the Product Purchase Please Fill In Tear off Fold and Mail this form to Reach us within 10 days of the Product Purchase We welcome your Valuable Suggestions if any to Improve our Products and Services We welcome your Valuable Suggestions if any to Improve our Products and Services FOR OFFICE USE ONLY FOR OFFICE USE ONLY Customer C...

Page 20: ...R No S IN INDIA BUSINESS REPLY ENVELOPE ONIDA CUSTOMER RELATION CENTRE Adonis Electronics Pvt Ltd Onida House II Mukund Ground Floor Mahal Industrial Estate off Mahakali Caves Road Andheri East Mumbai Maharashtra India 400093 ...

Reviews: