11
2hp 50hz Super Gorilla Owner’s Manual © O.A.S. 2010
IX. Filter Maintenance
External Filter Cartridge Cleaning Intervals
When unit is turned off, use compressed air to blow dust off from
exterior of fi lter. Hold nozzle at least 6” away from fi lter pleats*. Do
not remove bottom dust pan before or during the blow-off process!
Let dust settle into dust pan. Unclip and dump out dust. Filter
removal is not required.
*WARNING: A close, direct blast with the compressed air nozzle
too close to fi lter, may damage fi lter media. Always wear safety
glasses while blowing off fi lter.
Fan / Blower & Cyclone Outside Placement
Fan / Blower has a TEFC - Totally Enclosed Fan Cooled Motor.
Note: Use steel drum when placed outside.
Before Operation:
Mount system and connect cyclone and dust bin. Make sure dust bin is in place and ductwork is connected
to inlet before turning on the dust collector.
Electrical Wiring:
Make sure power source matches wire voltage confi gurations on motor.
Prior to connecting to the power line, check motor plate for proper voltage. Motor is pre-wired for counter-
clockwise rotation. Fan wheel must rotate counter-clockwise if looking down on fan housing.
Use 12 gauge cord for the fan / blowers.
Lubrication:
See pg. 19 for schedule and specifi cations.
Caution: Rotating Fan Blades! Keep objects clear of outlet.
Do not operate Fan / Blower unless Cyclone and Dust Bin are in place! Motor will overheat!
Caution: Fine dust collected in fi lter is hazardous to
your health! Do not breathe!
Shown with
optional
Stand.
Caution:
If exhaust air is vented outside you must provide make up / return air.
Flue gases (carbon monoxide) can be drawn into the shop from furnaces,
water heaters or other appliances.