background image

Customer Service Dept.

1-866-387-8822  •  [email protected]

1001 West Fayette Street, Syracuse, NY 13204 U.S.A.

Copyright © 2019 Oneida Air Systems, Inc.

Thank you for your business!

Regardless of where you purchased your system, if you have any 

questions or issues with missing / damaged parts, please call 
Oneida Air Systems first to let us help resolve your problem. 

We fully stand behind the quality of our product and place the 

utmost value on our customer’s opinion.

We want to do everything possible to make your purchase and 

experience with Oneida Air Systems a good one!

Summary of Contents for Mini-Gorilla

Page 1: ...Rev 12 12 2019 Doc ZBM000024A Appearance may vary slightly U S Patent 7824457 8377160 8491686 8496719 7937803 OWNER S MANUAL Mini Gorilla 110V 220V XXPM010100H XXPM010100H220...

Page 2: ......

Page 3: ...Contents System Start Up Information 2 System Specifications 4 System Dimensions 5 System Contents 6 Assembly Instructions 8 Maintenance 14 Troubleshooting 15 FAQ 16 Recommended Accessories 18 Warrant...

Page 4: ...0 17 of an inch in certain concentration ranges when ignited can deflagrate burn quickly An ignition source such as a spark or ember can ignite a dust mixture resulting in an expanding flame front whi...

Page 5: ...nformation on portable extinguishers can be found in NFPA 10 Standard for Portable Fire Extinguishers 11 Be especially careful with sanding units They can produce concentrations of dust in the combust...

Page 6: ...A 220v 8A On Off Switch Rocker Switch Power Cord 20 ft 6 m Power Connector 110v NEMA 5 20 220v NEMA 6 20 Recommended Circuit Size 20A Recommended CircuitType HACR Sound Emission 80 5 dBA 10 ft 3m IMPE...

Page 7: ...ystem Dimensions Top View 10 5 457 mm 28 711 mm 43 1 092 mm 18 457 2 mm 24 75 629 mm 52 25 1 327 mm 23 584 mm 110V 220V The Mini Gorilla requires a 20 Amp outlet receptacle to be installed by a licens...

Page 8: ...Mini Gorilla Hardware Kit 1 C9A VAB363602 22 Gal Heavy Duty Plastic Liner Bags 2 C9B VRV050500 1 2 ID Vinyl Tubing 5 ft C9C RGZ025050 Gasket 6 ft C9D ABF500000 1 2 Straight Fitting 2 C9E AFW180508 5 8...

Page 9: ...C8 C8 C8 C9G C9V C9U C9M C9Q C9N C9O C9P C9K C9L C9H C9I C9J C9S C9T C9R C9B Gasket Bag Components Gasket Bag Components Gasket Bag Components Leg Hardware Casters Leg Hardware Casters Motor Attachme...

Page 10: ...t without the washer this will pull the square shank through the round housing hole Once the carriage bolt is fed through the leg s hole remove the nut Secure in place with the washer and nut 1 Secure...

Page 11: ...the inner wall to secure it in place when securing the nut 3 4 Install each of the three Drum Casters C9M to the drum using two 1 4 Hex Head Bolts C9N two Rubber Washers C9O two 1 4 Flat Washers C9P...

Page 12: ...ould be finger tightened to help align the Motor Assembly A in Step 10 5 Insert a Drum Liner Bag C9A into the Drum making sure it fully expands against the sides and the bottom of the drum The top edg...

Page 13: ...hecking that the bolt holes are in alignment with the clip holes and installed in the correct orientation Otherwise you will not get the seal needed for complete dust collection There will be two left...

Page 14: ...rum Window C6 Note If U Spring Nuts C9R don t align with the motor plate holes use a screwdriver to adjust misalignment Hand tighten first and then tighten down 10 The motor assembly is very heavy and...

Page 15: ...ce with four 5 16 Flat Washers C9W and four Nylock Nuts C9X FIG 11b Note DO NOT overtighten 11 Place Filter Cap C9V onto the bottom port of the Filter B and secure in place using Band Clamp C9U 12 Ins...

Page 16: ...nd away from anyone in the area Do not use this method when any hazardous material has been vacuumed up 5 Check to make sure filter is in good condition with no torn media or cracks or tears in the se...

Page 17: ...e unit is not installed on a GFCI outlet breaker We recommend a 20A HACR type circuit breaker Poor dust pick up atTools System and ductwork connections 1 Check length of duct runs duct diameters and h...

Page 18: ...accordance to national state local NFPA OSHA and all other applicable codes Can I wall mount my Mini Gorilla to the wall Currently we do not have any wall mount solution available Is this product comp...

Page 19: ...on the 5 end Can I connect Flex Hose directly to the inlet Yes it will be a secure and firm fit I m having trouble attaching flex hose to the inlet do you have any tricks Start with the cut end of the...

Page 20: ...ith FlameGuard FCS101935HF Independently tested G E Certified H12 HEPA filter media Wide spaced pleated filters with teflon like coating for quick and easy dust removal Equipped with patented FlameGua...

Page 21: ...5 Hose Quick Connect Adapter Kit DQK050000 Includes both the crimped and non crimped quick release flex hose adapter fittings Made from heavy gauge galvanized steel Perfect when using a single connec...

Page 22: ...an effort to achieve better quality products SAFETY WARNING PLEASE READ Before Purchasing or Installing a dust collection system the buyer is cautioned to do so in accordance with prescribed Federal...

Page 23: ...21 oneida air com Notes...

Page 24: ...ess of where you purchased your system if you have any questions or issues with missing damaged parts please call Oneida Air Systems first to let us help resolve your problem We fully stand behind the...

Reviews: