background image

oneida-air.com 13

F.A.Q. 

Can I use 3rd party replacement filters? 

Yes, the BenchTop DC uses a standard 16 x 25 x 3" MERV-15 filter that can be sourced from most hardware 

stores. Double check the new filter's size before purchasing or installing.  Please see the Recommended 

Accessories section on page 14. Have spare filters on hand to not skip a beat. 

Is this item suitable for fume evacuation?  

No, the BenchTop DC is designed for airborne dust and particulate filtration. The Main Filter is not suitable for 

VOCs, acids, corrosives, or flammable fumes.

What particle size does it filter out? 

The BenchTop DC's dual filtration system captures up to 95% of particles as small as 0.3 microns in diameter. 

Does it come with a remote? 

No, it doesn't come with a remote. Please see the Recommended Accessories section on page 14 for options. 

Can I use it with an extension cord? Is there a maximum length?  

Yes, check the amperage rating on your cord to determine the maximum length.  

Will heat effect how the unit operates? 

The BenchTop DC can operate in most common shop temperatures, however it should not be used in 

environments exceeding 104°F (40°C).

I want it to run continuously. Is there a recommended length of time to run it for? 

The system can be run continuously as long as the environment's temperature does not exceed 104°F (40°C).     

Can I use this system as an ambient air cleaner?

We do not recommend ambient cleaners because on their own they are not effective at reducing airborne 

particulate to acceptable levels; Dust collectors need to be very close to the source of the dust emission to be 

effective.
However, if you desire to hang the BenchTop DC from the ceiling, the unit includes two integrated threaded 

inserts. Your ceiling joist or similarly strong mounting surface must be capable of supporting 20 lbs of weight 

and you will also need to supply your own fasteners and hangers; we recommend 1/4"-20 eye-bolts with 

shoulder. 

Summary of Contents for BenchTop DC

Page 1: ...BenchTop DC Personal Dust Collector XBZ000100 Rev 08 19 2020 Doc ZBM000041 Appearance may vary slightly OWNER S MANUAL...

Page 2: ......

Page 3: ...ents System Start Up Information 2 System Specifications and Dimensions 3 System Contents 4 Assembly Instructions 6 Features 9 Maintenance 10 Troubleshooting 12 F A Q 13 Recommended Accessories 14 War...

Page 4: ...d shop fire is to keep the shop clean A shop ankle deep in dust with layers of fine dust everywhere is an accident waiting to happen A good dust collection system reduces overall fire hazards but also...

Page 5: ...rd Length 6 PlugType NEMA 5 15P Noise Level 62 5 to 74 dBA SYSTEM DIMENSIONS AND CONSTRUCTION Primary Build Materials Cold Rolled Steel with a powder coated finish OverallWeight 20 lbs Pre Filter Dime...

Page 6: ...ion Qty A XBZ000100 BenchTop DC Assembly 1 B BTB000100 Fan Assembly 1 C FCS000001 Main Filter 1 D FCS162503 Pre Filter 1 E RBB000100 Frame Assembly 1 F BTV000001 LeftVane 1 ID Part number Part descrip...

Page 7: ...oneida air com 5 System Contents Continued B C D E F H J K I G...

Page 8: ...and right edge of the BenchTop DC Assembly as shown in FIG 1C Peel the backer tape off and adhere both pieces to the BenchTop DC Assembly A Turn the unit right side up Note Press each piece firmly on...

Page 9: ...e Top Vane G and settles into the lower right notch as shown in FIG 3b c Rotate the Right Vane H so that it is vertical and perpendicular to the Top Vane G Align and insert the two tabs of the Right V...

Page 10: ...lt in dust ports or bags It is meant to supplement those tools and create a cleaner zone of air around the user 5 Press the switch to the RESET position FIG 5a The fan speed can be adjusted as needed...

Page 11: ...ccepts standard C13 power cord 6 power cord included Switch Illuminates to indicate when the unit is on Draw Latch Ensures that the Fan Assembly and Frame Assembly remain firmly closed Auxiliary Power...

Page 12: ...est performance we highly recommend that you replace the Main Filter when it becomes too clogged to allow for adequate airflow See Recommended Accessories page 14 for the replacement filter part 6 The...

Page 13: ...hen installed 3 Push the Main Filter C into the Frame Assembly E up against the Pre Filter D while taking care not to touch the filter media or damage the Main Filter s frame 4 Align the Frame Assembl...

Page 14: ...y 1 Turn off and unplug the BenchTop DC and wait for the Fan Assembly to come to a complete stop and for the dust to settle 2 Remove back cover of the Fan Assembly with Phillips screw driver and check...

Page 15: ...Is there a maximum length Yes check the amperage rating on your cord to determine the maximum length Will heat effect how the unit operates The BenchTop DC can operate in most common shop temperature...

Page 16: ...C Aluminum Foil Acrylic Tape 150 Roll ATF000000 Engineered with an aggressive long lasting pressure sensitive adhesive that demonstrates superior bonding when exposed to both sub zero and elevated tem...

Page 17: ...P when connected to a HEPA certified vacuum 115V iVAC Pro Automated Dust Control Switch ARS115200 Includes 1 Remote Control with belt clip Switch receives signals from up to 40ft away in any direction...

Page 18: ...roducts and prices at any time As a manufacturer Oneida Air Systems reserves the right to change product specifications at any time in an effort to achieve better quality products SAFETY WARNING PLEAS...

Page 19: ...oneida air com 17 Notes...

Page 20: ...where you purchased your system if you have any questions or issues with missing damaged parts please call Oneida Air Systems first to let us help resolve your problem We fully stand behind the quali...