II. 2hp Commercial Configurations
1. No Filter - Vent Outside -
3. External Tube Filters -
2. External Cartridge Filter -
Cartridge Filter Media
1 Pleated Cartridge Filter 39 80 Sq. Ft. or 62 130 Sq. Ft.
Spun bonded Polyester BIA ZHI / 487 Test - Rated C
Captures 99.9% of Test Material between 0.2 - 2.0 microns
@ 11 FPM Face Velocity
Do NOT remove fabric straps from filter.
Tube Filter Media
12 oz. Needle Felted Polyester Tube Filters, singed on the inside.
10 to 1 air to cloth ratio is recommended.
FT-19 Tube Filters / 18.8 ft of filter area / 12 dia. x 6 long /
7.5 - 8 ceiling height
FT-25 Tube Filters / 25 ft of filter area / 12 dia. x 8 long /
9 - 10 ceiling height
FT-31 Tube Filters / 30 ft of filter area / 12 dia. x 10 long /
12 ceiling height
BIA ZHI / 487 Test - Rated C
Captures 99.5% of test material between 0.2 - 2.0 microns @ 11
FPM face velocity.
1. No Filter
Caution:
If exhaust air is vented outside you must provide make up / return air.
Flue gases (carbon monoxide) can be drawn into the shop from furnaces,
water heaters or other appliances.
2. External
Cartridge
Filter
3. External
Tube
Filter
2HP Commercial Wood Dust Collector Owners Manual
O.A.S. 2004
c
3
Silencer
included
w/ Filter
Silencer Included with Filter