VIII.  General Assembly Instructions - 

All Models

1.  Wire motor according to wiring diagram on page 13. Use

a  cord rated for a minimum of 20 Amps. Make sure the cord

you use is rated for the same power as the motor. Always

follow motor plate diagram and wire for correct rotation. 

(See

Wiring diagram section)

2.  Secure fan assembly to Bracket (See Bracket assembly

Pg. 8) then attach cyclone barrel with ductwork clamp ring to

the fan assembly. Check to see if rubber seal is attached to

barrel top.  Align the inlet of the cyclone in the proper direction

for the system. 

See Fig. 1

.

3.  Attach the cone to the barrel with the metal clamping ring.

Lightly tighten the ring bolt. It is important that there is no air

leakage between the cone and barrel of the collector. There

should be a black rubber seal between the cone and barrel.

See Fig. 2

4.  Attach flex hose to bottom of collector and to lid of dust bin.

Securely fasten hose clamps. Cut excess length of flex hose

if needed. Longer flex hoses are available for installations

requiring more height. There must be an air tight seal between

the collector and dust bin. 

See Fig. 3

5.  Make sure the dust bin lid sits securely and the rubber

gasket on the bin lid is in place on the barrel. Maintain an air

tight seal between cyclone and dust bin to prevent motor from

overheating

due to over amperage draw.

6.  Attach the ductwork from the woodworking machines to the

inlet of the collector.

7.  

For External Cartridge, Tube Filter or No Filter models

 see

following pages 10 and 11.

8.  On external filter models, attach Filter Plenum Assembly or

External Cartridge Assembly with 4 bolts. 

See Filter Assembly

Section, pages 10 & 11 for details.

Fan

Assembly

Cyclone

Barrel

Clamp

Ring

1

3

Collector

Hose Clamp

Hose Clamp

Flex Hose

Dust Bin

2

Barrel

Cone

Clamp

Ring

Wiring should be done by a licensed electrician!

Rubber

Seal

Outlet

Inlet

IMPORTANT:

Do not operate the collector until the dust bin is in place

and the connector is air tight or motor damage could result!

Stay clear of fan exhaust while collector is operating.

Quick

Release

Clamp

Rubber

Seal

Summary of Contents for 2 HP Commercial Cyclonic Dust Collector

Page 1: ...P Commercial Cyclonic Dust Collector Oneida Air Systems Inc 1001 West Fayette St Syracuse N Y 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Owner s Manual W O OD MAGAZI N...

Page 2: ......

Page 3: ...ent draw should not exceed maximum motor amperage OAS is not responsible for damage to motors caused by improper installation wiring or failure to follow these directions Caution The Direct Drive Fan...

Page 4: ...Filters 18 8 ft of filter area 12 dia x 6 long 7 5 8 ceiling height FT 25 Tube Filters 25 ft of filter area 12 dia x 8 long 9 10 ceiling height FT 31 Tube Filters 30 ft of filter area 12 dia x 10 lon...

Page 5: ...ction 64 25 21 7 Approx Wt 122 lbs w o drum or filter Static pressure and volume together determine a fan s performance Several factors such as layout of ductwork and diameter of openings can affect a...

Page 6: ...ilter area required FTS060000 72 L FTS080000 96 L FTP080000 with zippers 96 L No 5 gal bucket needed FTP100000 120 L Note Check drum height it will affect your bracket height Always check the actual s...

Page 7: ...enum 32 3 4 wide x 62 long x 12 high 4 hole double wide plenum 32 3 4 wide x 48 long x 12 high Offset Inlet Plenum Plenum will be 1 1 4 off wall 27 125 8 12 18 2hp Cyclone with Fan Plenum can go to th...

Page 8: ...3hp Connect to main duct run out to woodworking machines Cyclone Barrel Cyclone Preseparator separates 99 of the wood waste from the air stream Eliminates wear on the fan wheel and maintenance on the...

Page 9: ...with lag screws concrete anchors or other suitable hardware See Fig 2 3 Note When installing the brackets on a concrete wall mount 2 x 4 s between wall and brackets to stabilize and dampen vibration 4...

Page 10: ...sten hose clamps Cut excess length of flex hose if needed Longer flex hoses are available for installations requiring more height There must be an air tight seal between the collector and dust bin See...

Page 11: ...dia is added 10 2 HP Commercial Wood Dust Collector Owner s Manual O A S 2004 c External Filter Assembly 39 1 Attach cartridge with four bolts provided See Fig 1 2 If Filter requires additional suppor...

Page 12: ...it by a length of pipe or if the silencer option is added If filter cartridge is located away from the cyclone and motor additional square to round connectors and pipe can be purchased 2HP Commercial...

Page 13: ...spended above the floor at a height that will allow for a 5 gallon plastic bucket and tube filter to fit properly underneath A well sealed plywood box will make a good plenum for air distribution thro...

Page 14: ...r not to exceed or 10 of nameplate voltage Licensed electrician should make all electrical connections Inlet Outlet Outlet can be rotated and oriented independent of inlet Counter clockwise if looking...

Page 15: ...n Blower Cyclone Outside Placement Fan Blower has a TEFC Totally Enclosed Fan Cooled motor Motor should be protected from weather to extend motor life Note Use steel drum when placed outside Before Op...

Page 16: ...h x 27 1 4 w x 28 3 8 deep 55 gal same as 35 gal Part STZ020035 2 0 w 35 gal Part STZ020055 2 0 w 55 gal Splitter Kit Part SDK350907 Kit as shown w 2 35 gal fiber drums Part SDK550907 same w 55 gal fi...

Page 17: ...hat your filter is clean See filter cleaning directions Filter Clogging Caused By Large chips clogging the filter Check for a leak in the dust bin flex coupling or lid Check for split or torn flex cou...

Page 18: ...d combustible Air borne wood dust below 420 microns in size 017 of an inch in certain concentration ranges when ignited can deflagrate burn quickly An ignition source such as a spark or ember can igni...

Page 19: ...nty of Onondaga Oneida Air Systems shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our produ...

Page 20: ...Rinse off INSIDE of filter Let filter dry completely before reuse or keep a spare filter on hand 2 Empty Dust Bin All steps should be done with a dust mask and eye protection 3 Rinse with water Optio...

Page 21: ......

Reviews: