![Oneida Air Systems 2 HP Commercial Cyclonic Dust Collector Owner'S Manual Download Page 12](http://html1.mh-extra.com/html/oneida-air-systems/2-hp-commercial-cyclonic-dust-collector/2-hp-commercial-cyclonic-dust-collector_owners-manual_1635483012.webp)
External Filter Assembly 62
2. Attach cartridge with four bolts and black
thumb knobs provided. Bolt the Filter to the
Plenum Assembly. See Fig. 2.
3. Latch the Dust Bin to the bottom of the
Filter using the draw latches.
1. Bolt together the Blower and Plenum assembly using
the four 3/8 bolts supplied. Make sure the gasket is in
place between the Fan/Blower outlet and the Plenum Inlet.
See Fig. 1
Fig. 1
C rated spun bonded polyester
filter contains 130 sq. ft. of filter
area. The filter captures
between 0.2 - 2.0 microns of
test material at a face velocity
of 11 FPM.
4. If Filter requires additional support. Use the plate at the
top of the filter to support the filter assembly.
Note: Filter will require additional support if separated from
the cyclone unit by a length of pipe or if the silencer option
is added. If filter cartridge is located away from the cyclone
and motor, additional square-to-round connectors and pipe
can be purchased.
2HP Commercial Wood Dust Collector Owners Manual
O.A.S. 2004
c
11
X. Fan Outlet Transition, Silencer and Angle Iron Stand
3/8 bolts
Do not
remove
bands.
Fig. 2
Draw
Latches
Included
Silencer
2hp -
35 Gal. & 55 Gal.
2hp - 8.5
2hp - 27 1/4
2hp - 28 3/8
2hp -
35 Gal. & 55 Gal.
Note: Unit is top heavy.
Bolt stand to the floor
after installation.
If using the optional Silencer,
connect Silencer between the
fan / blower outlet and inlet of
the plenum. 8 I.D. x 12 O.D x
12 long. Lowers sound by
5 - 8 db.
Fan Outlet
Connect the square-to-round transition to the fan
housing
with (4) 3/8 bolts provided. Use (4) 1/2 x #8 sheet
metal screws or 5/32 aluminum pop rivets to connect
Silencer to Square to Round and Silencer to Plenum.
Plenum
3/8 bolts
Screws or
Rivets
Screws or
Rivets
86 7/8 95 7/8
85
94