Please note
that the following troubleshooting guide is designed for people with strong
computer hardware knowledge such as System Administrators and Engineers.
Power is on, but there is no Panel Display
A)
Enter BIOS setup program and then get into the Boot Display option. Check if the default
setting is [ Auto ]; if not, change the setting to [ Auto ] and press
F10
to save the settings.
B)
Due to the chipset limitation, while two displays are connected to the system, both display
contents will shrink and cannot show properly in size under DOS mode. After the system
booting completed and running under the Windows OS, the display will show in normal
size.
Cannot Detect HDD
A)
SATA cable is not connected properly to mainboard SATA1/SATA2 or it could be
defective.
B)
HDD power cable is not connected properly to the mainboard or it could be defective.
C)
Check CMOS setup, set SATA HDD to Auto detects.
D)
On-board IDE port could be defective.
Touch Panel Does not Work
A)
Check CMOS settings, COM port
needs to be “Enabled”. And check the IRQ from the
MB manual
C)
Check if the ELO driver has been properly installed. Or try to reinstall again
(Please refer to the ELO driver installation).
D)
Check that the ELO controller on COM port has been detected during the ELO driver
installation. If yes, than check that the flat cable from the ELO touch screen has been
properly connected to the ELO controller (
Attention:
Pin1 mark should be on the same
side as the ELO controller).
E)
Check that the ELO controller Green LED is blinking?
If no, there is no DC+5V support for the ELO controller from the mainboard.
F)
Touch screen controller could be defective or the touch panel could be defective.
ELO Touch Panel Cannot Calibrate Correctly
A)
Please replace the ELO controller, and re-calibrate. If this works, change back to the