background image

One Stop Systems, Inc.                                                                                                             OSS-KIT-EXP-4500 
Rev. A    

 

Page 9 

 

PCI Table 2: Pin-out for the External PCIe Cable Connector  

 

PIN # 

Signal 

Description 

Notes 

A1 

GND 

Ground reference for PCI 
Express transmitter Lanes 

 

A2 PETp0 

 

Differential PCI Express 
transmitter Lane 0 5 

A3 PETn0 

 

Differential PCI Express 
transmitter Lane 0 5 

A4 

GND 

GND Ground reference for 
PCI Express transmitter Lanes 

 

A5 PETp1 

 

Differential PCI Express 
transmitter Lane 1 5 

A6 PETn1 

 

Differential PCI Express 
transmitter Lane 1  

A7 

GND 

Ground reference for PCI 
Express transmitter Lanes 

 

A8 PETp2 

 

Differential PCI Express 
transmitter Lane 2 

A9 PETn2 

 

Differential PCI Express 
transmitter Lane 2 

A10 

GND 

Ground reference for PCI 
Express transmitter Lanes 

 

A11 PETp3 

 

Differential PCI Express 
transmitter Lane 3 

A12 PETn3 

 

Differential PCI Express 
transmitter Lane 3 

A13 

GND 

Ground reference for PCI 
Express transmitter Lanes

 

A14  

 

Differential 100MHz cable 
reference clock 

 

A15 CREFCLK 

 

Differential 100MHz cable 
reference clock 

 

A16 

GND 

GND Ground reference for 
cable reference clock 

 

A17 

SB_RTN 

Signal return for single ended 
sideband signals 

 

A18 

CPRSNT# 

Used for detection of whether 
a cable is installed and the 
downstream subsystem is 
powered 

 

A19 

CPWRON 

Turns power on / off to slave-
type downstream subsystems 

 

B1 

GND 

Ground reference for PCI 
Express receiver Lanes 

 

B2 PERp0 

 

Differential PCI Express 
receiver Lane 0 


 

B3 PERn0 

 

Differential PCI Express 
receiver Lane 0 


 

B4 

GND 

Ground reference for PCI 
Express receiver Lanes 

 

B5 PERp1 

 

Differential PCI Express 
receiver Lane 1 


 

B6 PERn1 

 

Differential PCI Express 
receiver Lane 1 


 

B7 

GND 

Ground reference for PCI 
Express receiver Lanes 

 

B8 PERp2 

 

Differential PCI Express 
receiver Lane 2 


 

B9 PERn2 

 

Differential PCI Express 
receiver Lane 2 


 

Summary of Contents for Max Express OSS-KIT-EXP-4500

Page 1: ...One Stop Systems Inc Host Cable Adapter User Manual Rev A User Manual PCIe x4 Host Cable Adapter HIB2 OSS KIT EXP 4500...

Page 2: ...onceptual architecture 4 2 Specifications 2 a Host interface board 5 2 b Host expansion board 5 3 Installation Instructions 3 a Connecting PCIe cable 6 3 b Removing PCIe cable 6 3 c Installation instr...

Page 3: ...ard HIB2 sits in the host machine and cables to the Host Expansion Board HEB2 The Host Expansion Board site in a CPCI CPCE Chassis Host interface board PCIe x4 cable Host expansion board One Stop Syst...

Page 4: ...3 3v One Stop Systems Inc OSS KIT EXP 4500 Rev A Page 4 Slo Al low profile height 3 35 PCIe x4 Connect Power on Cable Ready 2 713 Clock direction shown in Host configuration 1 c Host Expansion Board...

Page 5: ...Operating Environment Temperature range 0 to 50C 32 to 122F Relative Humidity 5 to 90 non condensing Shock 5 17 Hz 0 5 double amplitude displacement 7 2000Hz 1 5g acceleration Agency Compliance Design...

Page 6: ...backplane to an ATX power supply separate from the host system power supply 3 Insert the HIB2 x4 in target mode in the PCIe connector on the test backplane next to the ATX connector 4 Insert the PCIe...

Page 7: ...om cable Power LED PCIe Lane Status LEDs Power and Cable present LEDs CR2 CR4 CR6 CR8 CR3 CR5 CR7 CR9 Cable present LED 4 b Block Diagram LVPECL Clock Buffer Downstream x4 PCI Express Cable Connector...

Page 8: ...Test Clock 7 GND Ground JTAG4 Host Mode TDO Test Data Output Target Mode Test Clock 8 3 3V 3 3 V power N C Not connected 9 N C Host Mode Not connected Target Mode Test Power On N C Not connected 10 3...

Page 9: ...n3 Differential PCI Express transmitter Lane 3 5 A13 GND Ground reference for PCI Express transmitter Lanes A14 CREFCLK Differential 100MHz cable reference clock A15 CREFCLK Differential 100MHz cable...

Page 10: ...e power return B18 CWAKE Power management signal for wakeup events optional 1 3 B19 CPERST Cable PERST Notes 1 Optional signals that are not implemented are to be left as no connects on the board side...

Page 11: ...12 A14 CREFCLK Differential Pair CREFCLK A14 A15 CREFCLK CREFCLK A15 A17 SB_RTN Hook up Wire SB_RTN A17 A18 CPRSNT Hook up Wire CPRSNT A18 A19 CPWRON Hook up Wire CPWRON A19 B2 PERp0 Differential Pair...

Page 12: ...ock from the host system to the remote system SB_RTN Side Band ReTurN return path for single ended signals from remote systems CPRSNT Cable PReSeNT Indicates the presence of a device beyond the cable...

Page 13: ...One Stop Systems Inc OSS KIT EXP 4500 Rev A Page 13 5 Ordering Information OSS KIT EXP 4500...

Reviews: