This section describes countermeasures for temporary hardware problems. Check the
malfunction in this section before sending the hardware for repair.
9.Troubleshooting
7.
Function Transition Carts
Operationg
Display
Output
Device restarts during
operation.
No input signal received.
The measured values fluctuate
and are not stable depending
on day and time.
The main display remains on
[-----].
Abnormal distance is displayed
when the object is clearly
outside meaurement range.
is displayed on the
main display when the power
is turned ON.
Judgements not output to
external device.
Strange linear output levels.
• Is the power supply device connected correctly?
• Are the Interface and Calculating Units connected
correctly?
• Are all cables connected correctly?
• Is the signal line disconnected?
This problem may be due to temperature
characteristics. Execute zero reset periodically using
the standard object to correct this problem.
• Has a timing input been made while hold is enabled
and the trigger type has been set to
?
• If the hold function is enabled and the trigger type is
[UP] or [DOWN], has the self-trigger level been set
to an appropriate Value.
• This problem may occur due to the characteristics of
the sensor. Make sure that the distance to the
sensing object is appropriate.
• This problem may be solved by selecting a fixed
measurement gain in the measurement sensitivity
setting.
The laser of the sensor head has deteriorated.
Replase the Sensor Head.
• Are all cables connected correctly?
• Is the signal line disconnected?
• Are reset inputs short-circuited?
• Is the switch on the bottom of the Amplifier Unit set
to the correct position?
• Has the correct selection (voltage/current) been
made in the monitor focus settings?
• Linear output levels can be fine-tuned.
Problem
ITEM
Probable cause and possible countermeasure
8.Error Messages and Countermeasures
This section outlines the error messages displayed on the main display and the
countermeasures for those messages.
Display
Error
Countermeasure
The received light intensity is
saturated or a distance
measurement error hasoccurred.
The Sensor Head is
disconnected. The Amplifire
unit can not communicate
the sensor.
Two-sensor operation
communications data error
Error-bright
Error-channel
Error-channel
Error-dark
If this does not solve the problem, use a
suitable workpiece.
If this does not solve the problem, use a
suitable workpiece.
・
If two Amplifier Units have been connected,
turn OFF the power supply and check that
the Amplifier and Calculating Units are
connected correctly.
・
If only one Amplifier Unit is being used,
connect another Amplifier Unit temporarily
and turn OFF the two-sensor operation,
or initialize the settings data.
・
Change the mode for the CH1 Amplifier
Unit to RUN.
・
Turn OFF the power supply and check that
the Amplifier and Calculating Units are
connected correctly. Replace the Amplifier
Unit or the Calculating Unit if the above
countermeasures do not solve the
problem.
Turn OFF the power supply, check the
connection for the Sensor Head, and then
turn ON the power supply again.
When there is a possibility of received the
influence of the noise,the power supply of
the sensor is divided with other equipment
or high-voltage lines and power lines must
be wired separately from this sensor.
If this does not solve the problem, the
Sensor Head is defective. Replace the
Sensor Head.
Turn OFF the power supply, check the
wiring for the Amplifier unit, and then turn
ON the power supply again. If this does
not solve the problem, the amplifier unit is
defective. Replace the Amplifier unit.
Turn OFF the power supply, check that the
HIGH, PASS, and LOW output lines are
not short-circuited, then turn ON the
power supply again.
When the mutual interference
prevention setting is ON or
2-sensor operation setting is
ON, but only one Amplifier
Unit connected
The received light intensity is
insufficient or a distance
measurement error has occurred.
Sensor Head laser error
Error-head
Error-head
Error-head
Error-head
Error-memory
Error-head
Error-head
Error-head
Error-head
Error-head
Sensor Head EEPROM
data error
Sensor Head System error
Amplifier unit EEPROM
data error
Error-memory
Error-short
Error-system
One or all of the judgement
outputs are short-cuircuited.
Turn OFF the power supply, check the
wiring for the Amplifier unit, and then turn
ON the power supply again. If this does
not solve the problem, the amplifier unit
is defective. Replace the Amplifier unit.
Amplifier unit System error
The response time setting is more large
value. If this does not solve the problem,
use a suitable workpiece.
Smart tuning failed.
Tuning-failed
Replace the Sensor Head.
Measurements are displayed if entering the
state that measurements can be output.
Sensor Head laser
deterioration failure
LD.down
Measurements are not output by the
cause when the RESETsignal is
being input, and before the sampling
duration of holding the operations.
■
The easiest setting up
Single Smart Tuning
*Please see the user's manual about other setting.
operation
Place the work piece in
position and adjust the
Sensor Head position.
Refer to the Amplifier
Unit's display or Sensor
Head's indicators. And
adjust the Sensor Head
position so that the
upper and lower limits
of the height (H) to be
measured fall within the
measuring range.
When press the
button for one second, if
isplayed, separate from
the button. The single
smart tuning is executed.
When it is displayed
on sub display as
and flash for three
seconds, the single
smart tuning is failed.
Please change the
setting parameter, and
execute it again.
Display
Explanation of
operation
Explanation of
selection menu
―
―
Pressing
Separated
Flashing
Press for about
3 seconds
Press for about
3 seconds
When the detail menu
is selected on.
When the detail
menu is selected
off.
Press for about
3 seconds at the
same time
Press for 1 second
at the same time
Press for about
1 seconds
Press for 1 second
HIGH
Threshold
Response
Time
LOW
Threshold
Detail
Menu
Initialization
MENU MODE (Detail Menu OFF)
★:
Default Value
*
*The case of ZX2-LD50(L) (Firmware Ver1.2xx)has been described.
:
BANK
Analog
output
Analog
output
Resolution
Present
value
BANK
(数値設定)
(数値設定)
★
★
★
★
★
★
select: OFF
:
Sub Display
:
Main Display
select: ON
For unconnection
or CH1
For unconnection
or CH1
For unconnection
or CH1
When not connected or connected
as 1 channel unit
Response
Time
★
HIGH
Threshold
HIGH
Threshold
★
LOW
Threshold
LOW
Threshold
★
Hysteresis
width
★
★
2-sensor
operation
For CH2 or more
★
Zero reset
memory
★
Detail
Menu
★
Initialization
★
★
Zero reset
display
value
★
On delay
time
★
External
Input
★
Scaling
★
Analog
output
★
Non
measurement
setting
★
Clamp
level
Analog output setting is
-
5 to5V or 1 to 5V.
Analog output setting is
4 to20mA.
★
★
Off delay
time
Trigger setting is
TIMMING.
Hold setting is OFF.
Trigger
mode
Hold setting is
not OFF.
Trigger setting is
not TIMMING.
★
Hold
setting
★
Self trigger
level
★
Present value 2
before scaling
setting
★
Present value 1
after scaling
setting
★
Present value 1
before scaling
setting
★
★
Present value 2
after scaling
setting
MENU MODE (Detail Menu ON)
★
Thickness
setting
mode
2-sensor operation
setting is THICK.
2-sensor operation
setting is not THICK.
Hold setting is OFF.
Hold setting is ON.
★
Detect
For unconnection,
or CH2 or more
CH2 or more
CH2 or more
When connected as a
2 channel or later unit
Mutual
interference
prevention
For CH1
★
*The main display always shows the measured value.
*The numerals shown in the above diagram are an example only.
The actual display may be different.
*Do not move workpiece while pressing button.
The output is not updated while switching the sub-display.
RUN mode
*Smart tuning can be performed in menu mode.
*
Setting the Key Lock/
Releasing the Key Lock
Timing input
Smart Tuning
Zero Reset
Perform
Zero Reset
Release
±5V or 1 to 5V;
4 to 20mA;
RUN mode
BANK
★
Differentition
Sub-display
memory
★
Sub-display
memory
★
Suitability for Use
s
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
Oct, 2014
D
OMRON Corporation
Industrial Automation Company
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Regional Headquarters