Serial Communication
68
ZG2-DSU User’s Manual
Acquire Number of Connected Devices <CHGET command>
This command acquires the number of gang-mounted Sensor Controllers and Data
Storage Units.
<Command format>
<Response format>
<Explanation of parameters>
Example of response
Parameter No.
0 (default): Total number is acquired.
1: Number of connected Sensor Controllers is acquired.
2: Number of connected Data Storage Units is acquired.
Parameter No.
Configuration
0
1
2
ZG2-DSU+ZG2-WDC+ZG2-WDC
3
2
1
ZG2-DSU+ZG2-WDC
2
1
1
ZG2-WDC+ZG2-WDC
2
2
0
ZG2-WDC
1
1
0
C H G E T
CR
Parameter No.
E R
CR
CR
When processing ends successfully
When processing fails
Number