Judging Measurement Values (Alarm Outputs)
42
ZG2-DSU User’s Manual
Judging Measurement Values (Alarm Outputs)
Specifying Tasks
When outputting the judgment results of measurements as alarms, specify the channel
and task to be used for judgment.
FUN mode-[I/O SET]-[SOURCE]
Setting Judgment Conditions
Set the two values, HIGH and LOW thresholds, used for alarm output. Three judgment
results are output, [HIGH], [PASS] and [LOW]. Set the judgment conditions in the TEACH
mode.
Setting value
Description
CH
Selects the channel of the Sensor Controller targeted for alarm
judgment. (1, 2, default value: 1) CH2 is not displayed when it is not
connected.
TASK
Selects the task targeted for alarm judgment. (1-8)
HIGH
ON
OFF
ON
OFF
ON
OFF
LOW
PASS
HIGH threshold
Measurement
value
LOW threshold
Output
(ON when
measurement value >
HIGH threshold)
(ON when LOW
threshold
measurement value
HIGH threshold)
(ON when
measurement value <
LOW threshold)