Industrial Ethernet Connectors

   

XS5

@

-T / XS6

@

-T

Precautions

Correct Use

Do not use the Connectors in an atmosphere or environment that
exceeds the specifications. 

Connector Connection and Disconnection

When connecting or disconnecting Connectors, be sure to hold the
Connectors by hand.

Do not hold the cable when disconnecting Connectors.

When mating Connectors, be sure to insert the plug all the way to
the back of the socket before attempting to lock the Connectors.

Do not use tools of any sort to mate the Connectors. Always use
your hands. Pliers or other tools may damage the Connectors.

Wiring

Lay the cables so that external force is not applied to the 
Connectors. Otherwise, the degree of protection (IP67) may not
be achieved.

Degree of Protection

The degree of protection of Connectors (IP67) is not for a fully
watertight structure. Do not the Connectors underwater.

Do not step on or place any objects on the Connectors. Doing so
may damage the Connectors. 

General Precautions

Do not pull excessively on the Connectors or cables. Do not install
the Connectors or cables in any way that would place a load
directly on the mating section or cable connections. Doing so can
damage the Connectors or break the wires inside the cables.

Install the Connectors and cables where they will not be stepped
on to prevent the wires inside the cables from being broken and to
prevent the Connectors from being damaged. If the Connectors or
cables must be installed where they might be stepped on, protect
them with covers.

Refer to the specifications for your cables before bending the
cables and do not bend them past their minimum bending radius. 

Summary of Contents for XS5 T Series

Page 1: ...2 M12 Cable with Connectors on Both Ends M12 RJ45 Cable with Connectors on Both Ends RJ45 RJ45 RJ45 Assembly Connector M12 Connector for Panel Mounting Item Model XS5H T421 M0 K XS5W T421 M2 K XS5W T421 MC K XS5W T421 MD K XS6G T421 1 XS5P T42 5 Rated current 3 A 2 5 A 3 A Rated voltage 30 V Contact resistance 20 mΩ max Insulation resistance 500 MΩ min Withstand voltage 1 000 VAC for 60 s leak cur...

Page 2: ... 4 4 poles 4 Contact Plating 2 0 4 μm gold plating M12 connectors 5 Cable Connection Direction 1 Straight 6 Cable Length A 0 3 m G 5 m B 0 5 m J 10 m C 1 m K 15 m D 2 m E 3 m 7 Connections M A Yellow B White C Orange D Blue Numbers inside circles are terminal numbers 8 Connectors on One End Both Ends 0 One M12 Plug 9 Cable Specifications K UL CM PVC double shielded Cat 5E Type Cable length L m Mod...

Page 3: ... T421 CM2 K 2 XS5W T421 DM2 K 3 XS5W T421 EM2 K 5 XS5W T421 GM2 K 10 XS5W T421 JM2 K 15 XS5W T421 KM2 K Type Cable length L m Model Straight Cable with Connector on Both Ends M12 RJ45 0 3 XS5W T421 AMC K 0 5 XS5W T421 BMC K 1 XS5W T421 CMC K 2 XS5W T421 DMC K 3 XS5W T421 EMC K 5 XS5W T421 GMC K 10 XS5W T421 JMC K 15 XS5W T421 KMC K XS5W T421 M2 K 2 x M12 TM 1 4 3 2 44 7 44 7 L cable length M12 M12...

Page 4: ...ating RJ45 connectors 5 Cable Connection Direction 1 Straight 6 Cable Length A 0 3 m G 5 m B 0 5 m J 10 m C 1 m K 15 m D 2 m E 3 m 7 Connections M A Yellow B White C Orange D Blue Numbers inside circles are terminal numbers 8 Connectors on One End Both Ends 2 Two M12 Plugs C One M12 Plug One RJ45 Plug D Two RJ45 Plugs 9 Cable Specifications K UL CM PVC double shielded Cat 5E Type Cable length L m ...

Page 5: ...t 6 Contact 1 Applicable wires 6 1 to 6 9 dia Stranded wires AWG22 to AWG24 Solid wires AWG22 to AWG23 XS5P T42 5 Rear or Front locking M12 socket 20 18 13 9 dia 22 1 10 5 2 5 2 8 PG9 500 10 3 20 17 18 Yellow Blue White Orange M12 D Coding 15 3 Panel thickness t 1 to 4 dia 0 1 0 XS5P T427 5 Front Locking 17 18 14 6 dia 2 8 PG9 500 22 1 11 9 10 3 20 20 18 White Yellow Blue Orange 2 5 M12 D Coding W...

Page 6: ... be achieved Degree of Protection The degree of protection of Connectors IP67 is not for a fully watertight structure Do not the Connectors underwater Do not step on or place any objects on the Connectors Doing so may damage the Connectors General Precautions Do not pull excessively on the Connectors or cables Do not install the Connectors or cables in any way that would place a load directly on t...

Page 7: ...Industrial Ethernet Connectors XS5 T XS6 T 7 MEMO ...

Page 8: ...mburg IL 60173 847 882 2288 11 10 Specifications subject to change without notice All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale which can be found at http www components omron com components web webfiles nsf sales_terms html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces mu...