F-72
Two-circuit Limit Switch
WL
■
Characteristics
General-purpose Models/Environment-resistant Models
Note: 1.
The above figures are initial values.
2.
The figures in parentheses for dielectric strength, are those for the overtravel (high-sensitivity) model.
3.
The values are calculated at an operating temperature of 5
°
C to 35
°
C, and an operating humidity of 40% to 70%. Contact your OMRON
sales representative for more detailed information on other operating environments.
4.
10,000,000 operations min. for general-purpose, high-sensitivity, and flexible rod overtravel models.
5.
500,000 operations min. for high-precision and outdoor specifications models. All microload models however, are 1,000,000 operations
min.
6.
Except the flexible rod models. The shock resistance (malfunction) for microload models is 200 m/s
2
min.
7.
For low temperature models this is –40
°
C to 40
°
C (no icing). For heat-resistive models the range is +5
°
C to 120
°
C.
Degree of protection
IP67
Durability (See note 3.)
Mechanical: 15,000,000 operations min. (See note 4.)
Electrical:
750,000 operations min. (See note 5.)
Operating speed
1 mm to 1 m/s (for WLCA2)
Operating frequency
Mechanical: 120 operations/minute min.
Electrical:
30 operations/minute min.
Rated frequency
50/60 Hz
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Contact resistance
25 m
Ω
max. (initial value)
Dielectric strength
1,000 VAC (600 VAC), 50/60 Hz for 1 min between non-continuous terminals.
2,200 VAC, 50/60 Hz for 1 min/Uimp 2.5 kV non-current-carrying metal part and ground.
2,200 VAC, 50/60 Hz for 1 min Uimp 2.5 kV between each terminal and non-current-carrying metal
part.
Rated insulation voltage (U
i
)
250 V (EN60947-5-1)
Switching overvoltage
1,000 V max. (EN60947-5-1)
Pollution degree (operating environment)
3 (EN60947-5-1)
Short-circuit protective device (SCPD)
10 A, fuse type gG or gI (IEC269)
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional enclosed thermal current
(I
the
)
10 A, 0.5 A (EN60947-5-1)
Protection against electric shock
Class I
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude (See note 6.)
Shock resistance
Destruction: 1,000 m/s
2
min.
Malfunction: 300 m/s
2
min. (See note 6.)
Ambient temperature
Operating: –10
°
C to 80
°
C (with no icing) (See note 7.)
Ambient humidity
Operating: 95% max.
Weight
Approx. 275 g (in the case of WLCA2)