30
Section 2
2.
3 ID link
uni
t:
M
o
de
l V70
0
-L11
V700-L11
User's Manual
Section 2
Unit Specifications
2.3.3 Dimensional drawing and mounting method
∗
Be sure to limit the tightening torque for the M4 screws to 1.2 N-m or less.
∗
Do not apply an organic solvent such as thread glue to the threads. Otherwise, cracking can occur
on the case.
RS-232C connector
ID port connector
4 Status indicators
RS-485 connector
Mounting holes
2- 4.5
5
4
100
2-M4 or 4.2
55
110
41.5
41.3
26.5
18.5
20.3
65
16.7
10.7
60
35.2
4
Case material
PC/ABS resin
(Unit: mm)