4
Frequency inverters
Digital operator
Indicators
(setting/monitor
item indicators)
Data display
FREQUENCY
adjuster
Operation keys
Appearance
Name
Function
Data display
Displays relevant data items, such as frequency reference, output frequency,
and parameter set values.
Frequency adjuster
Sets the frequency reference within a range between 0 Hz and the maximum frequency.
1
Frequency reference indicator
The frequency reference can be monitored or set while this indicator is lit.
Output frequency indicator
The output frequency of the inverter can be monitored while this indicator is lit.
Output current indicator
The output current of the inverter can be monitored while this indicator is lit.
Multi-function monitor indicator
The values set in U01 through U10 are monitored while this indicator is lit.
Forward/reverse selection indicator
The direction of rotation can be selected while this indicator is lit when operating the inverter
with the RUN key.
Local/remote selection indicator
The operation of the inverter through the digital operator or according to the set parameters is
selectable while this indicator is lit.
2
Parameter setting indicator
The parameters in n001 through n179 can be set or monitored while this indicator is lit.
3
Mode key
Switches the simplified-LED (setting and monitor) item indicators in sequence.
Parameter being set will be canceled if this key is pressed before entering the setting.
Increment key
Increases multi-function monitor numbers, parameter numbers, and parameter set values.
Decrement key
Decreases multi-function monitor numbers, parameter numbers, and parameter set values.
Enter key
Enters multi-function monitor numbers, parameter numbers, and internal data values after they
are set or changed.
RUN key
Starts the inverter running when the 3G3MV is in operation with the digital operator
STOP/RESET key
Stops the inverter unless parameter n007 is set to disable the STOP key.
Used to reset the inverter when an error occurs.
4
1.
V7 IP65 types have digital operator without frequency adjuster.
2.
The status of the local/remote selection indicator can be only monitored while the inverter is in operation. Any RUN comand input is ignored while this
indicator is lit.
3.
While inverter is in operation, the parameters can be only monitored and only some parameters can be changed. Any RUN command is ignored while the
parameter setting indicator is lit.
4.
For safety reasons, the reset function cannot be used while an operation instruction (forward/reverse) is being input. Turn the operation instruction OFF
before using this function.
Varispeed V7
5
F
re
q
u
en
c
IP 20 type 0.1 to 4 Kw
IP20 / NEMA1 type 5.5/7.5 Kw
Dimensions
Voltage class
Max. applicable
motor output kW
Inverter model
CIMR V7AZ
Figure
Dimensions in mm
Weight kg
Cooling
method
W
H
D
W1
H1
H2
D1
Three-phase
200 V
0.12
20P1
1
68
128
76
56
118
5
10
0.6
Self cooled
0.25
20P2
0.6
0.55
20P4
108
42
0.9
1.1
20P7
128
62
1.1
Fan cooled
1.5
21P5
2
108
131
96
5
64
1.4
2.2
22P2
140
1.5
4.0
24P0
140
143
128
71
2.1
Single-phase
200 V
0.12
B0P1
1
68
128
76
56
118
5
10
0.6
Self cooled
0.25
B0P2
76
0.7
0.55
B0P4
131
42
1.0
1.1
B0P7
2
108
140
96
118
5
64
1.5
Fan cooled
1.5
B1P5
156
96
1.5
2.2
B2P2
140
163
128
71
2.2
4.0
B4P0
170
180
158
2.9
Three-phase
400 V
0.37
40P2
2
108
128
92
96
118
5
16
1.0
Self cooled
0.55
40P4
110
34
1.1
1.1
40P7
140
64
1.5
1.5
41P5
156
1.5
Fan cooled
2.2
42P2
1.5
3.0
43P0
140
143
128
71
2.1
4.0
44P0
2.1
Voltage class
Max. applicable
motor output kW
Inverter model
CIMR - V7AZ
Figure
Dimensions in mm (inches)
Weight kg
Cooling
method
W
H
D
W1
H1
H2
D1
Three-phase
200 V
5.5
25P5
3
180
260
170
164
244
8
65
4.6
Fan cooled
7.5
27P5
4.8
Three-phase
400 V
5.5
45P5
180
260
170
164
244
8
65
4.8
7.5
47P5
4.8
W 1
D
D1
8.5
(0.34)
W
H 2
H 1 H
2 M4
W 1
W
H 2
H 1 H
4 M4
D
8.5
(0.34)
D1
Figure 1
Figure 2
Figure 3
Varispeed V7
8