Frequency inverters
Type designation
200 V class
400 V class
Specifications
IP20 single-phase: CIMR-V7AZ
B0P1
B0P2
B0P4
B0P7
B1P5
B2P2
B4P0
IP65 single-phase: CIMR-V7TZ
---
---
B0P405
B0P705
B1P505
B2P205
---
IP20 three-phase: CIMR-V7AZ
20P1
20P2
20P4
20P7
21P5
22P2
24P0
Maximum permissible motor output kW
1
1.
Based on a standard 4-pole motor for maximum applicable motor output. Select the inverter model within the allowable motor rated current
0.12
0.25
0.55
1.1
1.5
2.2
4.0
O
u
tp
u
t
ch
ar
ac
te
ri
st
ic
s
Inverter capacity kVA
0.3
0.6
1.1
1.9
3.0
4.2
6.7
Rated output current A
0.8
1.6
3.0
5.0
8.0
11.0
17.5
Max. output voltage
Proportional to input voltage: 0..240 V
Max. output frequency
400 Hz
P
o
w
er
su
p
p
ly
Rated input voltage
and frequency
Single-phase 200..240 V 50/60 Hz
3-phase 200..230 V 50/60 Hz
Allowable voltage
fluctuation
-15%..+10%
Allowable frequency
fluctuation
+5%
IP20 three-phase: CIMR-V7AZ
40P2
40P4
40P7
41P5
42P2
43P0
44P0
45P5
47P5
IP65 three-phase: CIMR-V7TZ
40P405
40P705
41P505
42P205
43P005
44P005
Maximum permissible motor output kW
1
1.
Based on a standard 4-pole motor for maximum applicable motor output. Select the inverter model within the allowable motor rated current
0.37
0.55
1.1
1.5
2.2
3.0
4.0
5.5
7.5
O
u
tp
u
t
ch
ar
ac
te
ri
st
ic
s
Inverter capacity kVA
0.9
1.4
2.6
3.7
4.2
5.5
7.0
11.0
14.0
Rated output current A
1.2
1.8
3.4
4.8
5.5
7.2
9.2
14.8
18.0
Max. output voltage
Proportional to input voltage: 0..400 V
Max. output frequency
400 Hz
P
o
w
er
su
p
p
ly
Rated input voltage
and frequency
3-phase 380..460 VAC, 50/60 Hz
Allowable voltage
fluctuation
-15%..+10%
Allowable frequency
fluctuation
+5%
Voltage
B: Single-phase 200 VAC
2: Three-phase 200 VAC
4: Three-phase 400 VAC
Z: European standard specifications
Inverter
V7 series
A: With digital operator (with potentiometer)
T: V7 IP65 type with digital operator
( without potentiometer )
C I M R — V 7 A Z B 0 P 1 0
Max. applicable motor output
0P1: 0.1 kW
7P5: 7.5 kW
~
"P" indicates a decimal
point
[ ]
Protective enclosure:
0: IP20
1: NEMA1
05: IP65
Varispeed V7
3
Commom specifications
Model number
CIMR-V7AZ-
@
CIMR-V7TZ-
@
Specifications
C
o
n
tr
o
l f
u
n
ct
io
n
s
Control methods
Sine wave PWM (V/f control, sensorless vector control)
Output frequency range
0.1..400 Hz
Frequency tolerance
Digital set value: ±0.01% (-10..+50 ºC)
Analogue set value: ±0.5% (25 ±10 ºC)
Resolution of frequency set value
Digital set value: 0.01 Hz (<100 Hz), 0.1 Hz (>100 Hz)
Analogue set value: 1/1000 of maximum frequency
Resolution of output frequency
0.01 Hz
Overload capability
150%/60 s
Frequency set value
0..10 V (20 k
Ω
), 4..20 mA (250
Ω
), 0..20 mA (250
Ω
)
Pulse train input, frequency setting value (selectable)
Braking torque
(short term peak torque)
Up to 200 W 150% or more
550 W to 1.1 kW 100% or more
1.5 kW 50% or more
>1.5 kW 20% or more
Continuous braking torque approx. 20% without, 150% with external braking resistor
F
u
n
ct
io
n
al
it
y
Binary inputs
7 freely programmable inputs
Binary outputs
1 relay output, 2 freely programmable open collector outputs
Analogue output
1 programmable analogue output (0..10 V)/pulse output
Analogue inputs
2 analogue inputs, 0..10 V, 4..20 mA, 0..20 mA
Braking/acceleration times
0.01..6000 s
Display
Optionally frequency, current or set value
Error and status LED
P
ro
te
ct
io
n
f
u
n
ct
io
n
s
Motor overload protection
Electronic thermal overload relay
Instantaneous overcurrent
Motor coasts to a stop at approx. 250% of inverter rated current
Overload
Motor coasts to a stop after 1 minute at 150% of inverter rated output current
Overvoltage
Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class)
Undervoltage
Stops when DC bus voltage is approx. 200 V or less (double for 400 V class)
(approx. 160 V or less for single-phase series)
Momentary power loss
Following items are selectable: not provided (stop if power loss is 15 ms or longer), continuous operation
if power loss is approx. 0.5 s or shorter, continuous operation
Cooling fin overheat
Protected by electronic circuit
Stall prevention level
Individual levels during accel/constant speed. Decel ON/OFF available. During decel enable/disable selectable.
Cooling fan fault
Detected by electronic circuit (fan lock detection)
Ground fault
Protected by electronic circuit (operation level is approx. 250% of rated output current)
Power charge indication
RUN lamp stays ON or digital operator LED stays ON until the DC bus voltage becomes 50 V or less.
(Charge LED is provided for 400 V)
A
m
b
ie
n
t
co
n
d
it
io
n
s
Degree of protection
IP20, NEMA1, IP65
Cooling
Self cooling for 200 V 0.1..0.4 kW (3 or single phase) and for 400 V 0.2..0.75 kW
Cooling fan for 200 V 0.75 to 7.5 kW and for 400 V 1.5 to 7.5 kW
Ambient temperature
Open air mounting: -10 ºC..50 ºC
Wall mounting: -10 ºC..40 ºC
Ambient humidity
95% (without condensation)
Storage temperature
-20 ºC..+60 ºC (short-term temperature during transportation)
Installation
Indoor (no corrosive gas, dust, etc.)
Installation height
Max. 1000 m
Vibration
10 to 20 Hz, 9.8 m/s
2
max; 20 to 50 Hz, 2 m/s
2
max
Varispeed V7