59
Electromagnetic Inductive RFID System
User's Manual
S
E
CTI
O
N 4
En
d C
o
de
Lis
t
SECTION 4
Commands
End Code List
*1 Communications between the CF Reader/Writer and the Handy Terminal are called host communi-
cation.
*2 “7E” (lock error) and “7F” (tag error) most likely Tag errors. If these errors occur no matter how many
times communications are attempted, replace the Tag.
Refer to
for details on the indicator.
Type
End code
Name
Description
Normal end
00
Normal end
Command execution has ended correctly.
A command started executing normally when polling processing is specified.
Host
communications
error
*1
10
Parity error
A parity error has occurred in the characters in the command.
11
Framing error
A framing error has occurred in the characters in the command.
12
Overrun error
An overrun error has occurred in the characters in the command.
14
Format error
The command format is incorrect.
The character interval exceeds the set time.
18
Frame length error
A command string longer than 300 characters was received.
Tag
communications
error
70
Communications error
An error occurred during communications with a Tag, and the
communications could not be completed normally.
71
Verification error
The correct data could not be written to the Tag (only possible when
verification is enabled).
72
No-tag error
There is no Tag in the CF Reader/Writer communications area.
7A
Address designation
error
The designated processing address is not suitable, and the execution is
impossible.
7D
Write protection error
Data was written to a write-protected page.
7E
*2
Lock error
Write was specified for a locked area.
7F
*2
Tag error
Communications were attempted with a Tag for which communications are
not enabled (e.g., no password setting).