SECTION 4
Commands
Ranges for Start Address and Number of Bytes
The following table shows the commands and available designation range for specifying start
addresses and number of bytes in commands. If a value outside the available range is specified, a
command error will occur.
* If the start address is 20h and the number of bytes is 70h, the result is A + B = 90h, which gives a
command error.
Command code
Ranges for start address and number of bytes
Other restrictions
Read (RD)
A) Start address:
B) No. of bytes:
0000h to 007Fh
01h to 80h
A+B
≤
80h*
Write (WT)
A) Start address:
B) No. of bytes:
0000h to 007Fh
01h to 80h
A+B
≤
80h*
Computation Write (CW)
A) Start address:
B) Calculation area:
0000h to 007Fh
01h to 04h
A+B
≤
80h*
Data Fill (DF)
A) Start address:
B) End address:
0000h to 007Fh
0000h to 007Fh
A
≤
B
Memory Check (MD)
A) Start address:
B) No. of check bytes:
0000h to 007Dh
03h to 80h
A+B
≤
80h*