17
Electromagnetic Inductive RFID System
User's Manual
SEC
TI
O
N
2
Ta
g
s
SECTION 2
Communications Preparations
Tags
Installation Environment
Do not use Tags in the following locations.
•
Locations with corrosive gases, flammable gases, or dust
•
Locations with an ambient temperature not between
−
10 and 70
°
C and locations subject to sudden
temperature fluctuations that may cause condensation
•
Inside microwave ovens
Mounting Method
Observe the following precautions when mounting Tags.
•
Do not chip or make holes in Tags.
•
Do not apply excessive force to Tags.
•
Do not mount Tags side-by-side or close to metallic objects.
* Tags may warp if used in an environment subject to repeated high and low temperatures, but this will
not affect Tag functions.
■
V370-D13F01(H)
•
Mounting Direction
•
Mounting Example
Use two M3 screws to mount a Tag.
Marking surface
Mount section
20.5
±
0.1
Two, M3 holes
(Unit: mm)
Mounting Hole Dimensions
Summary of Contents for V670-CF01