Troubleshooting
75
■
From Trial Operation to Communications
Errors are indicated by the status of the indicators after transmission of the write command, and by the
response code of the response.
• If the ID Tag Was Processed Normally:
If there is no response to the write command, refer to the
From Installation to Trial Operation
,
Operation Check Flowchart
.
Refer to page 73.
Indicators
RUN
COMM
NORM
ERROR
Response Code for the Response
Type
Response
code
Function
Normal
00
The ID Tag was processed normally.
Error occurrence
Is the response
code 1
?
No
Yes
Check the command format.
If the response code is 1
Refer to page 76.
Yes
Communications with the ID Tag has failed.
If the response code is 7
Refer to page 76.
Write command sent
RUN indicator
OFF?
No
Yes
An error has occurred at the Amplifier Unit.
Amplifier Unit error
Is the response
code 7
?
Communications OK
No
(Lights once)
(Lights once)