![background image](http://html1.mh-extra.com/html/omron/v640-ham11-etn/v640-ham11-etn_user-manual_741374037.webp)
35
CIDRW System
User’s Manual
SECTION 3
Communica
tions
Te
st
SECTION 3
Preparing for Communications
Communications Test
Communications Test with the Host Device
A communications test is performed to confirm that the host device and Amplifier Unit are connected
correctly.
Refer to
Host Communications Specifications
.
R
A test is preformed for the Amplifier Unit using the data 12345678.
Command code
Test data
CR
Data 1
Data 2
Data 3
Data 4
1
0
1
2
3
4
5
6
7
8
0Dh
Response
code
Test data
CR
Data 1
Data 2
Data 3
Data 4
0
0
1
2
3
4
5
6
7
8
0Dh
Host
Amplifier Unit
Command
Response