WARRANTY 

OMRON’s exclusive warranty is that the products are

free from defects in materials and workmanship for a period of one
year (or other period if specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE
OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES
THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED
USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS
OR IMPLIED.

LIMITATIONS OF LIABILITY 

OMRON SHALL NOT BE RESPONSI-

BLE FOR SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CON-
NECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED ON CONTRACT, WARRANTY, NEGLIGENCE OR STRICT
LIABILITY.

In no event shall responsibility of OMRON for any act exceed the indi-
vidual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WAR-
RANTY, REPAIR OR OTHER CLAIMS REGARDING THE PROD-
UCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED
AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION,
ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR
REPAIR.

APPLICATION CONSIDERATIONS

SUITABILITY FOR USE 

OMRON shall not be responsible for confor-

mity with any standards, codes or regulations which apply to the
combination of the product in the customer's application or use of the
product.

At the customer's request, OMRON will provide applicable third party
certification documents identifying ratings and limitations of use
which apply to the product. This information by itself is not sufficient
for a complete determination of the suitability of the product in combi-
nation with the end product, machine, system, or other application or
use.

The following are some examples of applications for which particular
attention must be given. This is not intended to be an exhaustive list

of all possible uses of this product, nor is it intended to imply that the
uses listed may be suitable for this product:

• Outdoor use, uses involving potential chemical contamination or

electrical interference, or conditions or uses not described in this
catalog.

• Nuclear energy control systems, combustion systems, railroad sys-

tems, aviation systems, medical equipment, amusement machines,
vehicles, safety equipment, and installations subject to separate
industry or government regulations.

• Systems, machines and equipment that could present a risk to life

or property.

Please know and observe all prohibitions of use applicable to this
product.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING
THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS
PROPERLY RATED AND INSTALLED FOR THE INTENDED USE
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS 

OMRON shall not be responsible

for the user’s programming of a programmable product, or any con-
sequence thereof.

DISCLAIMERS

PERFORMANCE DATA 

Performance data given in this catalog is

provided as a guide for the user in determining suitability and does
not constitute a warranty. It may represent the result of OMRON’s
test conditions, and the user must correlate it to actual application
requirements. Actual performance is subject to the OMRON War-
ranty and Limitations of Liability.

CHANGE IN SPECIFICATIONS 

Product specifications and accesso-

ries may be changed at any time based on improvements and other
reasons. It is our practice to change part numbers when published
ratings or features are changed, or when significant construction
changes are made. However, some specifications of the product may
be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your appli-
cation. Please consult with your OMRON representative at any time
to confirm actual specifications of purchased product.

ERRORS AND OMISSIONS 

The information in this catalog has

been carefully checked and is believed to be accurate; however, no
responsibility is assumed for clerical, typographical or proofreading
errors, or omissions.

OMRON ON-LINE

Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.ca

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4

Cat. No. GC RFID 4 Printed in USA

OMRON CANADA, INC.

885 Milner Avenue
Toronto, Ontario M1B 5V8

416-286-6465

OMRON ELECTRONICS LLC

One Commerce Drive
Schaumburg, IL 60173

847-843-7900

For US technical support or other inquiries:

800-556-6766

5/03           Specifications subject to change without notice

Complete terms and conditions for product purchase and use are on Omron’s website at
www.omron.com/oei

 –

 under the “About Us” tab, in the Legal Matters section.

Summary of Contents for V600-HA

Page 1: ... consumption 130 mA max Input Transistor output or contact output Short circuit current 3 mA typical IN terminal and 0 V short circuit OFF voltage 15 to 30 VDC ON voltage 0 to 5 VDC Input impedance 8 2 kΩ Applied voltage 30 VDC max Transistor output OFF voltage 15 to 30 VDC Input impedance 8 2 kΩ Short circuit current 3 mA typical for 0 V short circuit of INHIBIT TRG ON voltage 0 to 5 VDC Applied ...

Page 2: ...ta output lines Interface Cable Note The interface cable connector is not waterproof If there is a possibility that the connector may be exposed to water keep it inside the control box The maximum cable length is 10 m Vibration resistance Destruction 10 to 150 Hz 0 3 mm double amplitude with 4 sweeps of 8 min each in 3 directions Destruction 10 to 150 Hz 1 5 mm double amplitude with 4 sweeps of 8 ...

Page 3: ...erature 10 to 60 C 10 to 70 C Storage temperature 25 to 75 C Ambient humidity 35 to 95 Insulation resistance 50 MΩ at 500 VDC between cable terminal and case Dielectric strength 1 000 VAC 50 60 Hz for 1 min between cable terminal and case leakage current 1 mA max Degree of protection IEC60529 IP67 Vibration resistance Destruction 10 to 2 000 Hz 3 mm double amplitude with 2 sweeps of 15 min each in...

Page 4: ...600 HS61 V600 HS63 V600 HS67 V600 D23P53 V600 D23P54 V600 D23P55 V600 D23P61 V600 D23P66N V600 D23P66SP V600 D23P72 V600 D23P71 V600 D8KR12 V600 D8KR04 V600 D2KR16 Wireless transmission Wireless transmission Terminal block wiring Connector connection Connector connection Connector connection Host Sensor Cable length fixed to 2 m Amplifier Cable length fixed to 0 5 m with connector interface Connec...

Page 5: ... Y 0 10 20 30 10 20 30 Y X 10 20 30 X Y V600 HS51 V600 D23P53 V600 HS51 V600 D23P54 V600 HS51 V600 D23P55 V600 HS51 V600 D23P61 V600 HS51 V600 D23P66N V600 HS51 V600 D8KR12 0 4 8 4 8 Y X 4 8 Y X Y X 0 4 8 12 4 8 12 Y X 4 12 8 0 5 10 15 5 10 15 5 10 15 Y X X Y 0 5 10 15 20 25 5 10 15 20 25 Y X 5 10 15 20 X Y 0 10 20 30 10 20 30 Y X 10 20 30 X Y 0 10 20 30 10 20 30 Y X 10 20 30 X Y V600 HS61 V600 D2...

Page 6: ...30 50 40 Y X 10 20 30 40 50 Y X 0 20 40 60 20 40 60 Y X 20 40 60 X Y 0 20 40 60 20 40 60 Y X 20 40 60 X Y 0 20 40 60 20 40 60 Y X 20 40 60 Y X 0 20 40 60 80 20 40 60 80 Y X 20 40 60 80 Y X 0 20 40 60 80 20 40 60 80 Y X 20 40 60 X Y V600 HS63 V600 D23P55 V600 HS63 V600 D23P61 V600 HS63 V600 D23P66N V600 HS63 V600 D23P66SP V600 HS63 V600 D23P71 V600 HS63 V600 D23P72 V600 HS63 V600 D8KR12 V600 HS63 V...

Page 7: ...80 20 40 60 80 60 20 40 Y 80 0 20 40 60 80 20 40 60 80 80 60 20 40 X Y Y X X 0 20 40 60 80 100 20 40 60 80 100 100 80 60 20 40 X Y Y X 0 20 40 60 80 100 20 40 60 80 100 100 80 60 20 40 X Y Y X 0 20 40 60 80 20 40 60 80 80 60 20 40 X Y Y X 0 20 40 60 80 20 40 60 80 80 60 20 40 X Y Y X 0 40 80 120 40 80 120 120 40 80 X Y Y X V600 HS67 V600 D23P66N V600 HS67 V600 D23P66SP V600 HS67 V600 D23P71 V600 H...

Page 8: ...0 HAM91 HAM81 otherwise an external input error may result 1 Maximum switching current 1 A min 2 Minimum switching current 10 mA min 3 Response time ON to OFF 3 ms min The following OMRON products cannot be connected to this product CVM1 OD219 C20H C28H C40H or C60H Programmable Controllers Sensor Controllers other than from the S3D2 Series When using a contact output pay careful attention to chat...

Page 9: ...ich carry large current such as motor drive cables near the V600 HA 91 81 92 Amplifiers conduct neces sary tests to make sure that the installation conditions are fully satis fied I O Interface Requirements 1 The TRG input must be 10 ms min 2 The INHIBIT input must be 20 ms min 3 Minimum of 5 ms is required as the transfer time of the Read Write Selection Input W R 4 The read data output must be r...

Page 10: ... Amplifier V600 HAR91 HAR81 Enlarged Section of Mounting Hole Two mounting holes Vinyl insulated round cord 5 8 mm dia 13 conductor cable standard length 0 5 m XG4E 2031 30û 4 4 5 5 30 21 17 5 28 3 36 3 61 8 89 8 2 98 68 5 55 30 80 35 2 500 mm 28 1 44 7 25 6 25 2 M4 89 0 2 21 0 2 Mounting Hole Dimensions ...

Page 11: ... Mounting Hole Two mounting holes Vinyl insulated round cord 5 8 mm dia 23 conductor cable standard length 0 5 m XG4E 2631 30 4 4 5 5 30 21 17 5 28 3 36 3 61 8 52 3 44 3 89 8 2 98 68 5 75 55 30 80 35 2 500 mm 28 1 52 3 25 6 25 2 M4 89 0 2 21 0 2 Mounting Hole Dimensions ...

Page 12: ...ound cord 5 8 mm dia 23 conductor cable standard length 0 5 m Mounting Hole Dimensions 35 49 5 33 7 M12X1 9 6 dia 13 7 dia Vinyl insulated round cord 4 mm dia Connector 2 lock washers 2 lock nuts Case Brass Transmission window ABS resin Filter Epoxy resin Cable PVC oil resistant 49 5 30 5 18 18 10 4 5 8 5 6 5 13 7 dia Vinyl insulated round cord 4 mm dia Connector Detection surface 12 0 2 2 3 5X5 m...

Page 13: ...2 R5 Bushing Power indicator green Case ABS resin Filter Epoxy resin Cable PVC oil resistant Connector Bushing Vinyl insulated round cord 6 mm dia 51 5 25 13 8 dia 10 10 11 30 20 Power indicator green 100 90 0 2 50 5 5 50 100 90 0 2 Four 4 5 dia mounting holes 14 Case ABS resin Filter Epoxy resin Cable PVC oil resistant Vinyl insulated round cord 9 mm dia 7 0 2 mm dia 13 conductor cable standard l...

Page 14: ...r V600 HAM91 HAM81 HAR92 Model L m V600 A60R 60M 2 V600 A61R 61M 5 V600 A62R 62M 10 Vinyl insulated round cord 9 mm dia 7 0 2 mm dia 23 conductor cable standard length 2 m XG5M 2632 N Connector 7 6 10 6 37 6 30 30 5 20 5 20 5 20 5 L 100 0 330 5 0 ...

Page 15: ...stems railroad sys tems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems machines and equipment that could present a risk to life or property Please know and observe all prohibitions of use applicable to this product NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE...