2
Intelligent Flag I/II
V600-HA
Intelligent Flag I/II
V600-HA
Innovative RFID Electronic Flags to
Replace Mechanical Flag and Kanban
Systems
• Doesn't need a program and can be used like a sensor.
• Advanced line construction at minimal cost.
• Saves space.
• Precise installation not required (Transmission distance:
100 mm max.).
• A verification function provided on multi-functional type.
• Addition of 16-bit models to the series responds to applica-
tions from Kanban to quality control.
• Equipped with a wiring reduction mode and communications
parity check function (16-bit models).
• Both NPN and PNP output available.
• FCC certified.
Ordering Information/Specifications
■
Amplifier
Type
Read-only (8-bit)
Multi-functional (8-bit)
Read-only (16-bit)
Item Model
V600-HAR91
V600-HAR81
V600-HAM91
V600-HAM81
V600-HAR92
Power supply
24 VDC ±10%, ripple (p-p): 10%
Current consumption
130 mA max.
Input
Transistor output or contact output
Short-circuit current: 3 mA (typical) (IN terminal and 0-V short-circuit)
OFF voltage:
15 to 30 VDC
ON voltage:
0 to 5 VDC
Input impedance:
8.2 k
Ω
Applied voltage:
30 VDC max.
Transistor output
OFF voltage:
15 to 30 VDC
Input impedance:
8.2 k
Ω
Short-circuit current:
3 mA (typical) (for 0-V short-circuit of
INHIBIT/TRG)
ON voltage:
0 to 5 VDC
Applied voltage:
30 VDC max.
Output
NPN open collector
output, 20 mA max. at
30 VDC, residual volt-
age: 2 V max.
PNP open collector
output, 20 mA max.
at 30 VDC, residual
voltage: 2 V max.
NPN open collector
output, 20 mA max. at
30 VDC, residual volt-
age: 2 V max.
PNP open collector out-
put, 20 mA max. at 30
VDC, residual voltage: 2 V
max.
NPN open collector output, 20 mA
max. at 30 VDC, residual voltage: 2 V
max.
Diagnostic functions
Checks for CPU errors and transmission errors
Insulation resistance
50 M
Ω
max. (at 500 VDC) between cable terminals and case
Dielectric strength
500 VAC, 50/60 Hz for 1 min between cable terminals and case (leakage current: 1 mA max.)