Output Circuit Diagram

DC 2-wire Models

DC 3-wire Models

Operating 

status

Model

Timing chart

Output circuit

NO

TL-W5MD1

NC

TL-W5MD2

Operating 

status

Model

Timing chart

Output circuit

NO

TL-W1R5M

#

1

TL-W3M

#

1

TL-W5M

#

1

NC

TL-W3M

#

2

TL-W5MC2

NO

TL-W1R5B1
TL-W3MB1
TL-W5MB1

NC

TL-W3MB2
TL-W5MB2

NO

TL-W5E1
TL-W20ME1

NC

TL-W5E2
TL-W20ME2

Sensing object

(%)

100

0

80(TYP)

Stable sensing

zone

Non-sensing

zone

Unstable
Sensing zone

Setting position

Proximity Sensor

ON

OFF

ON

OFF

ON

OFF

Setting indicator (green)

Operation indicator (red)

Control output

Rated sensing distance

Load

Brown

Blue

Main
circuit

+V

0V

Note: 
The Load can be connected to either the +V and 0-V side.

Proximity Sensor

Sensing zone

Non-sensing zone

Sensing
object

(%)

0

ON

OFF

ON

OFF

Operation indicator (red)

Rated sensing distance

100

Control output

Sensing object

Yes

No

Output transistor 

(load)

ON

OFF

Operation indicator

(red)

ON

OFF

*

* Maximum load current: 100 mA

Output

Load

Brown

Black

Blue

100

W

Main
circuit

+V

0V

Sensing object

Yes

No

Output transistor 

(load)

ON

OFF

Operation indicator

(red)

ON

OFF

Sensing object

Yes

No

Output transistor 

(load)

ON

OFF

Operation indicator

(red)

ON

OFF

Load

Brown

Black

Blue

100

W

Main
circuit

+V

0V

Sensing object

Yes

No

Output transistor 

(load)

ON

OFF

Operation indicator

(red)

ON

OFF

Sensing object

Yes

No

Operate
Release

Load

(between brown and black)

Output voltage

(between blue and black)

H

L

Operation indicator (red)

ON

OFF

Load

Brown

+V

Tr

Black

*2

*1

* Maximum load current: 100 mA
* 2. Current flows in this direction
if the circuit incorporates the transistor.

2.2

W

4.7k

W

100

W

Blue

0V

Output

Main
circuit

Sensing object

Yes

No

Operate
Release

Load

(between brown and black)

Output voltage

(between blue and black)

H

L

Operation indicator (red)

ON

OFF

F502-EN2-04.book  Seite 57  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for TL-W

Page 1: ...ilable These model numbers take the form TL W5MD 5 e g TL W5MD15 TL W5MD2 1 5mm Shape Sensing distance Output specifications Model Output and operating status PNP NO PNP NC NPN NO NPN NC DC 3 wire TL W1R5MB1 TL W1R5MC1 1 1 Models with different response frequency are available These model numbers take the form TL W5MD 5 e g TL W5MD15 TL W3MB1 TL W3MB2 TL W3MC1 1 TL W3MC2 TL W5MB1 TL W5MB2 TL W5MC1...

Page 2: ...on set indicator Green LED D2 models Operation indicator Red LED Operating status with sensing object approaching D1 models NO D2 models NC Protective circuits Surge absorber short circuit protection Ambient temperature Operating Storage 25 C to 70 C with no icing or condensation Ambient humidity Operating Storage 35 to 95 RH with no condensation Temperature influence 10 max of sensing distance at...

Page 3: ...tor lamp Detection indicator red LED Operating status with sensing object approaching NO C1 models NO C2 type NC E1 models F1 models NO E2 models F2 models NC Protective circuits Reverse connection protection surge absorber Ambient temperature Operating Storage 25 C to 70 C with no icing or condensation Ambient humidity Operating Storage 35 to 95 RH with no condensation Temperature influ ence 10 m...

Page 4: ...of sensing object d mm Brass Aluminum Iron Copper Stainless steel SUS304 7 6 5 4 3 2 1 0 10 20 30 40 50 60 Brass Aluminum Iron Copper Stainless steel SUS304 Sensing distance X mm Side length of sensing object d mm d t 1mm X 6 5 4 3 2 1 0 5 10 15 20 25 30 35 40 45 Sensing distance X mm Side length of sensing object d mm Brass Aluminum Iron Stainless steel SUS304 d t 1mm X 24 22 20 18 16 14 12 10 8 ...

Page 5: ...ator red Rated sensing distance 100 Control output Sensing object Yes No Output transistor load ON OFF Operation indicator red ON OFF Maximum load current 100 mA Output Load Brown Black Blue 100W Main circuit V 0V Sensing object Yes No Output transistor load ON OFF Operation indicator red ON OFF Sensing object Yes No Output transistor load ON OFF Operation indicator red ON OFF Load Brown Black Blu...

Page 6: ...er ate an error pulse for approximately 1 ms NO TL W5F1 NC TL W5F2 Operating status Model Timing chart Output circuit Sensing object Yes No Operate Release Load between brown and black Output voltage between blue and black H L Operation indicator red ON OFF Brown V Tr Black 2 1 2 2W 4 7kW Blue 0V Output Main circuit 100W Load 1 Maximum load current 200 mA 2 Current flows in this direction if the c...

Page 7: ...ttachment TL W5M 30 5 12 5 18 8 5 4 5 4 18 10 8 7 5 6 5 5 3 5 1 TL W5MC1 Vinyl insulated round cable with three conductors 4 dia conductor cross sectional area 0 2 mm2 insulation diameter 1 2 mm standard length 2 m TL W5MD Vinyl insulated round cable with two conductors 4 dia conductor cross sectional area 0 3 mm insulation diameter 1 3 mm standard length 2 m 2 C type Operation indicator red D typ...

Page 8: ... of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No E221 E2 03 X ...

Reviews: