DC 3-wire Models

Model

Item

TL-W1R5M

#

1

TL-W3M

##

TL-W5M

##

TL-W5E

#

/F

#

TL-W20ME

#

Sensing distance

1.5 mm ±10%

3 mm ±10%

5 mm ±10%

20 mm ±10%

Setting distance

0 to 1.2 mm

0 to 2.4 mm

0 to 4 mm

0 to 16 mm

Differential distance

10% max.

1% to 15% of 
sensing distance

Sensing object

Ferrous metal (refer to Engineering Data for non-ferrous metal on page E-55)

Standard sensing 
object

Iron, 8 x 8 x 1 mm

Iron, 12 x 12 x 
1 mm

Iron, 18 x 18 x 1 mm

Iron, 50 x 50 x 
1 mm

Response frequency 1 kHz min.

600 Hz min.

500 Hz min.

300 Hz min.

40 Hz min.

Power supply 
(Operating voltage 
range)

12 to 24 VDC (10 to 30 VDC) ripple (p-p): 10% max.

10 to 30 VDC with a ripple (p-p) of 
20% max.

12 to 24 VDC (10 
to 30 VDC) ripple 
(p-p): 10% max.

Current consumption 15 mA max. at 24 VDC (no-load)

10 mA max.

15mA max. at 24 VDC (no-load)

8 mA at 12 VDC, 
15 mA at 24 VDC

Control 
output

Switching 
capacity

NPN open collector 100 mA max. 
(30 VDC max.)

NPN open col-
lector 12 VDC 
50 mA max. 
(30 VDC max.)
24 VDC 100 mA 
max. (30 VDC 
max.)

200 mA

12 VDC 
100mA max., 
24 VDC 
200 mA max.

Residual 
voltage

1 V max. (under load current of 
100 mA with cable length of 2 m)

1 V max. (under 
load current of 
50 mA with cable 
length of 2 m)

2 V max. (under load current of 
200 mA with cable length of 2 m)

1 V max. (under 
load current of 
200 mA with ca-
ble length of 2 m)

Indicator lamp

Detection indicator (red LED)

Operating status 
(with sensing object 
approaching)

NO

C1 models: NO
C2 type: NC

E1 models, F1 models: NO
E2 models, F2 models: NC

Protective circuits

Reverse connection protection, surge absorber

Ambient temperature Operating/Storage: -25°C to 70°^C (with no icing or condensation)

Ambient humidity

Operating/Storage: 35% to 95%RH (with no condensation)

Temperature influ-
ence

±10% max. of sensing distance at 23°C within the temperature range of -25°C and 70°C

Voltage influence

±2.5% max. of sensing distance 
within a range of ±10% of rated 
power supply voltage

±2.5% max. 
of sensing dis-
tance within a 
range of ±20% 
of rated power 
supply voltage

±2.5% max. of sensing distance within a range of ±10% 
of rated power supply voltage

Insulation resistance 50 M  min. (at 500 VDC) between energized parts and case

Dielectric strength

1000 VAC 50/60 Hz for 1 min between energized part and case

Vibration resistance

10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 500 m/s

2

 for 3 times each in X, Y, and Z directions

Destruction: 
500 m/s2 for 10 
times each in X, 
Y, and Z direc-
tions

Protective structure

IEC60529 IP67

Connection method

Pre-wired models (standard length: 2 m)

Weight 
(Packed state)

30 g

Approx. 45 g

Approx. 70 g

Approx. 180 g

Material

Case

Heat-resistant ABS resin

Diecast aluminum

Heat-resistant 
ABS resin

Sensing 
surface

Heat-resistant ABS resin

Accessories

Mounting bracket,
 instruction manual

Instruction manual

F502-EN2-04.book  Seite 55  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for TL-W

Page 1: ...ilable These model numbers take the form TL W5MD 5 e g TL W5MD15 TL W5MD2 1 5mm Shape Sensing distance Output specifications Model Output and operating status PNP NO PNP NC NPN NO NPN NC DC 3 wire TL W1R5MB1 TL W1R5MC1 1 1 Models with different response frequency are available These model numbers take the form TL W5MD 5 e g TL W5MD15 TL W3MB1 TL W3MB2 TL W3MC1 1 TL W3MC2 TL W5MB1 TL W5MB2 TL W5MC1...

Page 2: ...on set indicator Green LED D2 models Operation indicator Red LED Operating status with sensing object approaching D1 models NO D2 models NC Protective circuits Surge absorber short circuit protection Ambient temperature Operating Storage 25 C to 70 C with no icing or condensation Ambient humidity Operating Storage 35 to 95 RH with no condensation Temperature influence 10 max of sensing distance at...

Page 3: ...tor lamp Detection indicator red LED Operating status with sensing object approaching NO C1 models NO C2 type NC E1 models F1 models NO E2 models F2 models NC Protective circuits Reverse connection protection surge absorber Ambient temperature Operating Storage 25 C to 70 C with no icing or condensation Ambient humidity Operating Storage 35 to 95 RH with no condensation Temperature influ ence 10 m...

Page 4: ...of sensing object d mm Brass Aluminum Iron Copper Stainless steel SUS304 7 6 5 4 3 2 1 0 10 20 30 40 50 60 Brass Aluminum Iron Copper Stainless steel SUS304 Sensing distance X mm Side length of sensing object d mm d t 1mm X 6 5 4 3 2 1 0 5 10 15 20 25 30 35 40 45 Sensing distance X mm Side length of sensing object d mm Brass Aluminum Iron Stainless steel SUS304 d t 1mm X 24 22 20 18 16 14 12 10 8 ...

Page 5: ...ator red Rated sensing distance 100 Control output Sensing object Yes No Output transistor load ON OFF Operation indicator red ON OFF Maximum load current 100 mA Output Load Brown Black Blue 100W Main circuit V 0V Sensing object Yes No Output transistor load ON OFF Operation indicator red ON OFF Sensing object Yes No Output transistor load ON OFF Operation indicator red ON OFF Load Brown Black Blu...

Page 6: ...er ate an error pulse for approximately 1 ms NO TL W5F1 NC TL W5F2 Operating status Model Timing chart Output circuit Sensing object Yes No Operate Release Load between brown and black Output voltage between blue and black H L Operation indicator red ON OFF Brown V Tr Black 2 1 2 2W 4 7kW Blue 0V Output Main circuit 100W Load 1 Maximum load current 200 mA 2 Current flows in this direction if the c...

Page 7: ...ttachment TL W5M 30 5 12 5 18 8 5 4 5 4 18 10 8 7 5 6 5 5 3 5 1 TL W5MC1 Vinyl insulated round cable with three conductors 4 dia conductor cross sectional area 0 2 mm2 insulation diameter 1 2 mm standard length 2 m TL W5MD Vinyl insulated round cable with two conductors 4 dia conductor cross sectional area 0 3 mm insulation diameter 1 3 mm standard length 2 m 2 C type Operation indicator red D typ...

Page 8: ... of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No E221 E2 03 X ...

Reviews: