background image

TL-N/TL-Q/TL-G

DC 3-Wire Models

AC 2-Wire Models

Operation 

mode

Model

Timing chart

Output circuit

NO

TL-Q2MC1
TL-Q5MC1

NC

TL-Q5MC2

NO

TL-N5ME1
TL-N10ME1
TL-N20ME1

NC

TL-N5ME2
TL-N10ME2
TL-N20ME2

Transistor

output

TL-G3D-3

Operation 

mode

Model

Timing chart

Output circuit

NO

TL-N5MY1
TL-N10MY1
TL-N20MY1

NC

TL-N5MY2
TL-N10MY2
TL-N20MY2

Present

Not present 

ON

OFF

ON

OFF

Output transistor 
(load)

Sensing object

Detection indicator 
(red)

100

Ω

0 V

+V

*

Load

Brown

Black

Output

Blue

Proximity

Sensor

main

circuit

* Load current: 100 mA max., TL-Q2MC1

Load current: 50 mA max., TL-Q5MC1

Present

Not present 

ON

OFF

ON

OFF

Output transistor 
(load)

Sensing object

Detection indicator 
(red)

Present

Not present 

Operate

Reset

High

Low

ON

OFF

Load (between brown 
and black leads)

Sensing object

Detection indicator (red)

Output voltage (between 
black and blue leads)

2.2

Ω

4.7 k

Ω

100

Ω

0 V

Tr

+V

*1

Load

Brown

Black

*1. Load current: 200 mA max. 

*2. When a transistor is connected. 

Output

*2

Blue

Proximity

Sensor

main

circuit

Present

Not present 

Operate

Reset

High

Low

ON

OFF

Load (between brown 
and black leads)

Sensing object

Detection indicator (red)

Output voltage (between 
black and blue leads)

Present

Not present 

ON

OFF

Output transistor 
(load)

Sensing object

0 V

+V

Load

Brown

Black

Output

Blue

Proximity

Sensor

main

circuit

* Load current: 20 mA max.

*

Present

Not present 

Operate

Reset

ON

OFF

Load

Sensing object

Operation indicator (red)

Brown

Blue

Load

Proximity

Sensor

main

circuit

Present

Not present 

Operate

Reset

ON

OFF

Load

Sensing object

Operation indicator (red)

http://www.ia.omron.com/

8

(c)Copyright OMRON Corporation 2007   All Rights Reserved. 

Summary of Contents for TL-G Series

Page 1: ... relying on the information therein All referenced brands product names service names and trademarks are the property of their respective owners 00000005981LF 000 EOS Power Buy Now We have 45 000 LP502030 PCM NTC LD A02554 EEMB Lithium Battery Rectangular 3 7V 250mAh Rechargeable in stock now Starting at 0 034 This EEMB part is fully warrantied and traceable 1 855 837 4225 Give us a call Internati...

Page 2: ...re TL M 5 example TL N5ME15 1 Models are also available with 5 m cables Add the cable length to the model number example TL N5ME1 5M 2 Models with robotics cables are also available Add R to the end of the model number example TL N5ME1 R Appearance Sensing distance Model Operation mode NO NC 17 17 TL Q5MD1 TL Q5MD2 25 25 TL N7MD1 TL N7MD2 30 30 TL N12MD1 TL N12MD2 40 40 TL N20MD1 TL N20MD2 Unshiel...

Page 3: ...ators D1 Models Operation indicator red Setting indicator green D2 Models Operation indicator red Operation mode with sensing object approaching D1 Models NO D2 Models NC Protection circuits Load short circuit protection Surge suppressor Ambient temperature range Operating Storage 25 to 70 C with no icing or condensation Ambient humidity range Operating Storage 35 to 95 with no condensation Temper...

Page 4: ...its Reverse polarity protection Surge suppressor Surge suppressor Ambient temperature range Operating Storage 10 to 60 C with no icing or condensation Operating Storage 25 to 70 C with no icing or condensation Ambient humidity range Operating Storage 35 to 95 with no condensation Temperature influence 10 max of sensing distance at 23 C in the temperature range of 10 to 60 C 20 max of sensing dista...

Page 5: ... indicator red Operation mode with sensing ob ject approaching E1 Y1 Models NO E2 Y2 Models NC Refer to the timing charts under I O Circuit Diagrams on page 8 for details Protection circuits E Models Reverse polarity protection Surge suppressor Y Models Surge suppressor Ambient temperature range Operating Storage 25 to 70 C with no icing or condensation Ambient humidity range Operating Storage 35 ...

Page 6: ... TL N12MD TL N20MD Y X Distance X mm Distance Y mm TL N7MD Sensing Head TL N12MD Sensing Head TL N20MD Sensing Head 2 0 1 5 1 0 0 5 0 80 100 120 140 160 180 200 220 240 260 mA V Leakage current mA Power supply voltage V AC power 50 60 Hz Protective resistance Proximity Sensor output OFF 5 4 3 2 1 0 3 5 10 30 50 100 300 500 1 000 Residual output voltage V Load current mA A 100 80 60 40 20 0 3 5 10 ...

Page 7: ...tainless steel SUS304 Aluminum Iron Copper Brass 6 5 4 3 2 1 0 5 10 15 20 25 30 35 40 45 X d d Distance X mm Side length of sensing object d mm Stainless steel SUS304 Aluminum Iron Brass 6 5 4 3 2 1 0 10 20 30 40 50 60 70 80 X d d t 1 mm Distance X mm Side length of sensing object d mm Stainless steel SUS304 Aluminum Iron Brass 10 8 6 4 2 0 10 20 30 40 50 60 X d d t 1 mm Distance X mm Side length ...

Page 8: ...1 TL N7MD1 TL N12MD1 TL N20MD1 NC TL Q5MD2 TL N7MD2 TL N12MD2 TL N20MD2 0 80 TYP 100 Sensing object Rated sensing distance Stable sensing area Non sensing area Unstable sensing area Set position Proximity Sensor ON OFF ON OFF ON OFF Setting indicator green Operation indicator red Control output V 0 V Load Brown Blue Proximity Sensor main circuit Note The load can be connected to either the V or 0 ...

Page 9: ...High Low ON OFF Load between brown and black leads Sensing object Detection indicator red Output voltage between black and blue leads 2 2 Ω 4 7 kΩ 100 Ω 0 V Tr V 1 Load Brown Black 1 Load current 200 mA max 2 When a transistor is connected Output 2 Blue Proximity Sensor main circuit Present Not present Operate Reset High Low ON OFF Load between brown and black leads Sensing object Detection indica...

Page 10: ... Mutual Interference When installing Sensors face to face or side by side ensure that the minimum distances given in the following table are maintained Mutual Interference Unit mm Values in parentheses apply to Sensors operating at different frequencies Mutual Interference Unit mm Mutual Interference Unit mm WARNING Precautions for Correct Use Model Distance A B TL Q5M 20 20 TL N7MD 40 35 TL N12MD...

Page 11: ...m Sensors Model Torque TL Q2MC1 0 59 N m TL Q5M TL N M 0 9 to 1 5 N m TL G3D 3 2 N m 5 15 min Material Iron t 0 5 mm 10 min Sensing object 1 mm max TL Q2MC1 8 2 5 28 25 8 9 1 6 18 5 0 2 Sensing surface 3 2 dia mounting hole Detection indicator red 2 9 dia vinyl insulated round cable with 3 conductors Conductor cross section 0 15 mm2 Insulator diameter 0 9 mm Standard length 2 m TL Q5M 16 3 17 17 1...

Page 12: ...wo 4 5 dia or M4 holes Mounting Hole Dimensions 18 5 0 5 25 6 2 25 18 0 2 50 1 5 34 1 18 0 45 46 3 Two 4 3 dia Operation indicator red Rubber bushing 6 dia vinyl insulated round cable with 2 conductors Conductor cross section 0 5 mm2 Insulator diameter 1 9 mm Standard length 2 m Two 4 5 dia or M4 holes TL N5MY Mounting Hole Dimensions 35 8 21 5 52 5 0 5 30 30 7 7 22 0 45 49 Two 4 3 dia 1 1 5 22 0 ...

Page 13: ...tor red Two 5 5 dia or M5 holes TL N20MD TL N20ME TL N20MY Mounting Hole Dimensions 1 Two M4 12 0 2 18 0 2 6 5 4 5 2 3 9 5 25 3 5 20 32 Applicable Models TL N5ME 2 Applicable Models TL N5MY Applicable Models TL N7MD 2 Y92E C5 Two M4 1 16 0 2 22 0 2 7 4 5 2 3 14 5 30 4 18 34 20 Applicable Models TL N10ME 2 Applicable Models TL N10MY Applicable Models TL N12MD 2 Y92E C10 Two M5 1 22 0 2 30 0 2 9 5 5...

Page 14: ...lt The load short circuit protection function op erates when the power supply is connected with the correct polarity and the power is within the rated voltage range DC 3 Wire NPN Output Sensors DC 2 Wire Sensors Even with the load short circuit protection function protection will not be provided when a load short circuit occurs if the power supply polarity is not correct Incorrect Wiring Be sure t...

Page 15: ...istive load Non contact control system Inductive load Relay solenoid etc Steady state current inrush current Operating reset voltage current Lamp load Steady state current inrush current Open close frequency Load Selecting the power supply type DC DC S3D2 Controller AC Control output Maximum current voltage Leakage current Residual load voltage The environmental tolerance of the Proximity Sensor i...

Page 16: ...s affected by magnetism or static capacitance from an adjacent Sensor and the output is unstable One means of avoiding interference when mounting Proximity Sensors close together is to alternate Sensors with different frequencies The model tables indicate whether different frequencies are available Please refer to the tables When Proximity Sensors with the same frequency are mounted together in a ...

Page 17: ...do not use a Proximity Sensor to turn the power supply ON and OFF for electronic devices that use DC half wave rectification In such a case use a relay to turn the power supply ON and OFF and check the system for operating stability after connecting it Examples of Timers that Use AC Half wave Rectification Timers H3Y H3YN H3RN H3CA 8 RD2P and H3CR A A8 AP F G Countermeasures for Leakage Current Ex...

Page 18: ...nsert the front of the Sensor into the special Mounting Bracket included or DIN Track 2 Press the rear of the Sensor into the special Mounting Bracket or DIN Track When mounting the side of the Sensor using the special Mounting Bracket first secure the Amplifier Unit to the special Mounting Bracket and then mount the special Mounting Bracket with M3 screws and flat washers with a diameter of 6 mm ...

Page 19: ... in series with an AND circuit the limit is three Sensors Be careful of the VS value in the diagram at left OR parallel connection In general it is not possible to use two or more Proximity Sensors in parallel with an OR circuit A parallel connection can be used if A and B will not be operated simulta neously and there is no need to hold the load The leakage current however will be n times the val...

Page 20: ...D M1J T is 5 V Model Type of connection Connection Description DC 3 wire AND series connection Keep the number of connected Sensors N within the range of the following equation iL N 1 i Upper limit of Proximity Sensor control output VS N VR Operating load voltage Note When an AND circuit is connected the operation of Proximity Sensor B causes power to be supplied to Proximity Sensor A and thus err...

Page 21: ... or hot concentrated sulfuric acid Maintenance and inspection Periodic Inspection To ensure long term stable operation of the Proximity Sensor inspect for the following on a regular basis Conduct these inspections also for control devices 1 Shifting loosening or deformation of the sensing object and Proximity Sensor mounting 2 Loosening bad contact or wire breakage in the wiring and connections 3 ...

Page 22: ...d may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations System...

Reviews: