TL-N/TL-Q/TL-G
Accessories (Order Separately)
Mounting Brackets
Ratings and Specifications
DC 2-Wire Models
* The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
Type
Model
Applicable Sensors
Provided with these Sensors
Order separately
Mounting Brackets
Y92E-C5
TL-N5ME
@
, TL-N7MD
@
TL-N5MY
@
Y92E-C10
TL-N10ME
@
, TL-N12MD
@
TL-N10MY
@
Y92E-C20
TL-N20ME
@
, TL-N20MD
@
TL-N20MY
@
Mounting Brackets for Conduits
Y92E-N5C15
---
TL-N5ME
@
, TL-N5MY
@
Y92E-N10C15
---
TL-N10ME
@
, TL-N10MY
@
Item
Model
TL-Q5MD
@
TL-N7MD
@
TL-N12MD
@
TL-N20MD
@
Sensing distance
5 mm
10%
7 mm
10%
12 mm
10%
20 mm
10%
Set distance
0 to 4 mm
0 to 5.6 mm
0 to 9.6 mm
0 to 16 mm
Differential travel
10% max. of sensing distance
Detectable object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data
on page 5.)
Standard sensing
object
Iron, 18
18
1 mm
Iron, 30
30
1 mm
Iron, 40
40
1 mm
Iron, 50
50
1 mm
Response
frequency
*
500 Hz
300 Hz
Power supply voltage
(operating voltage
range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current
0.8 mA max.
Control
output
Load
current
3 to 100 mA
Residual
voltage
3.3 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators
D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
Operation mode
(with sensing object
approaching)
D1 Models: NO
D2 Models: NC
Protection circuits
Load short-circuit protection, Surge suppressor
Ambient
temperature range
Operating/Storage:
25 to 70
C (with no icing or condensation)
Ambient
humidity range
Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
10% max. of sensing distance at 23
C in the temperature range of
25 to 70
C
Voltage influence
2.5% max. of sensing distance at rated voltage in the rated voltage
15% range
Insulation resistance
50 M
:
min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC for 1 min between current-carrying parts and case
Vibration
resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s
2
3 times
each in X, Y, and Z directions
Destruction: 1,000 m/s
2
10 times each in X, Y, and Z directions
Degree of protection
IEC 60529 IP67, in-house standards: oil-resistant
Connection method
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state)
Approx. 45 g
Approx. 145 g
Approx. 170 g
Approx. 240 g
Materials
Case
Heat-resistant ABS
Sensing
surface
Accessories
Instruction manual
Mounting Bracket, Instruction manual
Refer to the timing charts under
I/O Circuit Diagrams
on page 7 for details.
http://www.ia.omron.com/
2
(c)Copyright OMRON Corporation 2007 All Rights Reserved.