background image

xii

Related Manuals 

Name

Cat. No.

Contents

SYSMAC One NSJ Series
NSJ5-TQ

@@

(B)-G5D, NSJ5-SQ

@@

(B)-G5D, 

NSJ8-TV

@@

(B)-G5D, NSJ10-TV

@@

(B)-G5D, 

NSJ12-TS

@@

(B)-G5D, NSJ5-TQ

@@

(B)-M3D, 

NSJ5-SQ

@@

(B)-M3D, NSJ8-TV

@@

(B)-M3D, 

NSJW-ETN21, NSJW-CLK21-V1, NSJW-IC101
NSJ Controllers Operation Manual

W452 
(this 
manual)

Provides an outline of, and describes the design, installa-
tion, maintenance, and other basic operations for the NSJ-
series NSJ Controllers. Information is also included on fea-
tures, system configuration, wiring, I/O memory allocations, 
and troubleshooting.

Use together with the CJ-series 

Programmable Controllers 

Operation Manual 

(W393), CS/CJ-series 

Programmable 

Controllers Programming Manual 

(W394), and 

NS-Series 

Programmable Terminals Setup Manual

 (V083).

SYSMAC CJ Series 
CJ1G-CPU

@@

, CJ1M-CPU

@@

, CJ1G-CPU

@@

P, 

CJ1G/H-CPU

@@

H, CJ1H-CPU

@@

H-R

Programmable Controllers Operation Manual

W393

Provides an outline of, and describes the design, installa-
tion, maintenance, and other basic operations for the CJ-
series PLCs. Information is also included on features, sys-
tem configuration, wiring, I/O memory allocations, and trou-
bleshooting.

Use together with the CS/CJ-series 

Programmable Control-

lers Programming Manual 

(W394).

SYSMAC CS/CJ Series 
CS1G/H-CPU

@@

-EV1, CS1G/H-CPU

@@

H, 

CS1D-CPU

@@

H, CS1D-CPU

@@

S, CJ1G-

CPU

@@

, CJ1M-CPU

@@

, CJ1G-CPU

@@

P, 

CJ1G/H-CPU

@@

H, CJ1H-CPU

@@

H-R, NSJ

@

-

@@@@

(B)-G5D, NSJ

@

-

@@@@

(B)-M3D

Programmable Controllers Programming Manual

W394

Describes programming, tasks, file memory, and other func-
tions for the CS-series, CJ-series, and NSJ-series PLCs.

Use together with the 

Programmable Controllers Operation 

Manual

 (W339 for CS-series PLCs and W393 for CJ-series 

PLCs).

SYSMAC CS/CJ Series 
CS1G/H-CPU

@@

-EV1, CS1G/H-CPU

@@

H, 

CS1D-CPU

@@

H, CS1D-CPU

@@

S, CJ1G-

CPU

@@

, CJ1M-CPU

@@

, CJ1G-CPU

@@

P, 

CJ1G/H-CPU

@@

H, CJ1H-CPU

@@

H-R, NSJ

@

-

@@@@

(B)-G5D, NSJ

@

-

@@@@

(B)-M3D

Programmable Controllers Instructions Refer-
ence Manual

W340

Describes the ladder diagram programming instructions 
supported by CS-series, CJ-series, and NSJ-series PLCs. 
Use together with the 

Programmable Controllers Operation 

Manual

 (W339 for CS-series PLCs and W393 for CJ-series 

PLCs), and 

Programmable Controllers Programming Man-

ual

 (W394).

SYSMAC CS/CJ Series 
CS1G/H-CPU

@@

-EV1, CS1G/H-CPU

@@

H, 

CS1D-CPU

@@

H, CS1D-CPU

@@

S, CJ1G-

CPU

@@

, CJ1M-CPU

@@

, CJ1G-CPU

@@

P, 

CJ1G/H-CPU

@@

H, CJ1H-CPU

@@

H-R, CP1H-

X

@@@@

-

@

, CP1H-XA

@@@@

-

@

, CP1H-

Y

@@@@

-

@

, NSJ

@

-

@@@@

(B)-G5D, NSJ

@

-

@@@@

(B)-M3D, CS1W-SCB21-V1/41-V1, 

CS1W-SCU21-V1, CJ1W-SCU21-V1/41-V1
Communications Commands Reference Manual

W342

Describes the C-series (Host Link) and FINS communica-
tions commands used with CS-series, CJ-series, CP-series, 
and NSJ-series PLCs. 

This manual describes only communications commands 
addressed to the CPU Unit without regard to the communi-
cations path. (Communications are possible via the serial 
ports on the CPU Unit, ports on Serial Communications 
Boards/Units, Communications Units, etc.) Refer to the 
operation manual for the relevant Unit for commands 
addressed to Special I/O Units and CPU Bus Units. 

NS Series
NS5-SQ

@@

(B)-V1/V2, NS5-TQ

@@

(B)-V2, 

NS5-MQ

@@

(B)-V2, NS8-TV

@@

(B)-V1/V2,

NS10-TV

@@

(B)-V1/V2, NS12-TS

@@

(B)-V1/V2

Programmable Terminals Setup Manual

V083

Provides an outline of, and describes the design, installa-
tion, maintenance, and other basic operations for the NS-
series PTs. Information is also included on connecting to 
hosts and Programming Devices, and settings required for 
communications and PT operation. 

NS Series
NS5-SQ

@@

(B)-V1/V2, NS5-TQ

@@

(B)-V2, 

NS5-MQ

@@

(B)-V2, NS8-TV

@@

(B)-V1/V2,

NS10-TV

@@

(B)-V1/V2, NS12-TS

@@

(B)-V1/V2

Programmable Terminals Programming Manual

V073

Describes the functions of NS-series PTs, including screen 
configurations, object functions, and host communications 
for the PT.

Summary of Contents for SYSMAC One NSJ Series

Page 1: ...ss mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer...

Page 2: ...ANUAL Cat No W452 E1 06 SYSMAC One NSJ Series NSJ5 TQ B G5D NSJ5 SQ B G5D NSJ8 TV B G5D NSJ10 TV B G5D NSJ12 TS B G5D NSJ5 TQ B M3D NSJ5 SQ B M3D NSJ8 TV B M3D NSJW ETN21 NSJW CLK21 V1 NSJW IC101 NSJ...

Page 3: ......

Page 4: ...J Series NSJ5 TQ B G5D NSJ5 SQ B G5D NSJ8 TV B G5D NSJ10 TV B G5D NSJ12 TS B G5D NSJ5 TQ B M3D NSJ5 SQ B M3D NSJ8 TV B M3D NSJW ETN21 NSJW CLK21 V1 NSJW IC101 NSJ Controllers Operation Manual Revised...

Page 5: ...iv...

Page 6: ...some OMRON products often means word and is abbreviated Wd in documentation in this sense The abbreviation PLC means Programmable Controller PC is used how ever in some Programming Device displays to...

Page 7: ...PLC Information Using the Unit Manufacturing Information This method can be used for Special I O Units and CPU Bus Units as well Note CX Programmer version 6 1 or higher is required to go online with...

Page 8: ...t Manufacturing Information In the IO Table Window right click and select Unit Manufacturing informa tion CPU Unit The following Unit Manufacturing information Dialog Box will be displayed Use the abo...

Page 9: ...n 1 2 3 1 Simultaneously press two of the touch panel s four corners The System Menu will be displayed 2 Press the Special Screen Button The following screen will be displayed 3 Press the System Versi...

Page 10: ...ting Procedures 27 2 1 Overall Operating Procedure 28 2 2 Installing the USB Driver 28 2 3 Operating Procedure for the Controller Section 35 2 4 Operating Procedure for the Display Section 36 SECTION...

Page 11: ...3 8 8 Special Screens 164 8 9 Hardware Check 175 SECTION 9 Ladder Monitor 177 9 1 Using the Ladder Monitor 178 9 2 Starting the Ladder Monitor 178 9 3 Exiting Ladder Monitor 182 SECTION 10 Error Proce...

Page 12: ...Cat No CJ Series PLC Operation Manual W393 CS CJ Series PLC Programming Manual W394 CS CJ Series PLC Instructions Reference Manual W474 CS CJ Series PLC Communications Commands Reference Manual W342...

Page 13: ...CJ1G CPU CJ1M CPU CJ1G CPU P CJ1G H CPU H CJ1H CPU H R NSJ B G5D NSJ B M3D Programmable Controllers Instructions Refer ence Manual W340 Describes the ladder diagram programming instructions supported...

Page 14: ...its Operation Manual Construction of Applications W421 Provides information on constructing host applications for 100Base TX Ethernet Units including functions for send ing receiving mail socket servi...

Page 15: ...ns Section 5 describes how to install and wire the NSJ series NSJ Controller Section 6 section provides information on functionality added to the PLC Setup I O Allocations and I O Memory of the NSJ Co...

Page 16: ...S DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE OMRON DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE...

Page 17: ...that the uses listed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this manual Nuclear...

Page 18: ...onfirm actual specifications of purchased products DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes even when tolerances are shown PERFORMANC...

Page 19: ...xviii...

Page 20: ...must read this section and understand the information contained before attempting to set up or operate an NSJ Controller 1 Intended Audience xx 2 General Precautions xx 3 Safety Precautions xx 4 Oper...

Page 21: ...sure to read this manual before attempting to use the NSJ Con troller and keep this manual close at hand for reference during operation WARNING It is extremely important that the NSJ Controller be use...

Page 22: ...mal signals caused by broken signal lines momentary power interruptions or other causes Serious accidents may result from abnormal operation if proper measures are not provided WARNING The NSJ Control...

Page 23: ...HR Areas the contents of which can be held during power interrupts is backed up by a battery If a battery error occurs the con tents of the areas that are set to be held may not be accurate even thou...

Page 24: ...ricity or other forms of noise Locations subject to strong electromagnetic fields Locations close to power lines Locations subject to possible exposure to radioactivity Caution The operating environme...

Page 25: ...ing the terminals Do not perform withstand voltage tests on the NSJ Controller The allowable thickness of the panel for mounting is between 1 6 and 4 8 mm Secure the mounting bracket with a uniform ti...

Page 26: ...of bare stranded wires may result in burning Do not connect more than two crimp terminals to the same termi nal Check switch settings the contents of the DM Area and other prepara tions before starti...

Reviews: