101
Procedures
Section 3-2
Note
If a non-boolean data type is used for the input variable and only a numerical
value (e.g., 20) is input, the value for the CIO Area address (e.g, CIO 0020)
will be passed, and not the numerical value. To set a numerical value, always
insert an &, #, + or
−
prefix before inputting the numerical value.
Example Programs:
If the input variable data type is boolean and a numerical value only (e.g.,
0 or 1) is input in the parameter, the value for CIO 000000 (0.00) or
CIO 000001 (0.01) will be passed. Always input P_Off for 0 (OFF) and
P_On for 1 (ON).
REAL
Real number
32 bits
Positive value: & or + followed
by real number (with decimal
point)
Negative value:
−
followed by
real number (with decimal
point)
−
3.402823
×
10
38
to
−
1.175494
×
10
−
38
, 0, +1.175494
×
10
−
38
to +3.402823
×
10
38
LREAL
Long real number
64 bits
−
1.79769313486232
×
10
308
to
−
2.22507385850720
×
10
−
308
,
0, +2.22507385850720
×
10
−
308
to +1.79769313486232
×
10
308
WORD
16-bit data
16 bits
# followed by hexadecimal
number (4 digits max.)
& or + followed by decimal
number
#0000 to FFFF or &0 to 65535
DWORD
32-bit data
32 bits
# followed by hexadecimal
number (8 digits max.)
& or + followed by decimal
number
#00000000 to FFFFFFFF or &0
to 4294967295
LWORD
64-bit data
64 bits
# followed by hexadecimal
number (16 digits max.)
& or + followed by decimal
number
#0000000000000000 to
FFFFFFFFFFFFFFFF or &0 to
18446744073709551615
Input variable data
type
Content
Size
Input method
Setting range
10
DATA_1
&10
DATA_1
( INT )
( INT )
Instance for function block definition A
If the data format for DATA_1 is INT, and "10" is input,
the value for CIO 0010 will be passed.
Instance for function block definition A
If the data format for DATA_1 is INT, and the prefix &
is added so that "&10" is input, the numerical value
will be passed.
Summary of Contents for SYSMAC CX-Programmer 9
Page 2: ......
Page 4: ...iv ...
Page 6: ...vi ...
Page 8: ......
Page 16: ...xvi ...
Page 20: ...xx ...
Page 26: ...xxvi Application Precautions 4 ...
Page 27: ...Part 1 Function Blocks ...
Page 28: ......
Page 154: ...128 Procedures Section 3 2 ...
Page 155: ...Part 2 Structured Text ST ...
Page 156: ......
Page 160: ...134 CX Programmer Specifications Section 4 2 ...
Page 206: ...180 Procedures Section 6 1 ...
Page 208: ...182 System defined external variables supported in function blocks Appendix A ...
Page 230: ...204 Revision History ...
Page 231: ......