No.16S019-05
31/62
STC-SBS312POE / STC-SCS312POE / STC-SBS500POE / STC-SCS500POE
Product Specifications and User’s Guide
Exposure Timing with the Positive Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the active pulse width of the input trigger signal is less than
“LineDebounceTime” setting time. Please input more than “LineDebounceTime” time active pulse width of the
trigger signal.
Note 2: The exposure will start “LineDeboun photocoupler delay” time after the rising edge of the input trigger
signal.
Exposure Timing with the Negative Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the active pulse width of the input trigger signal is less than
“LineDebounceTime” setting time. Please input more than “LineDebounceTime” time active pulse width of the
trigger signal.
Note 2: The exposure will start “LineDeboun photocoupler delay” time after the falling edge of the input trigger
signal.
T1'
Trigger Signal
Exposure Time
Exposure Time:T1' = T1
T1
Debounce *Note1
Trigger Signal
(With Photocoupler delay)
Less than
15us
T1
Input Trigger signal
Exposure time
Exposure Time:T1' = T1
T1
Debounce
Filtering *Note.1
Trigger signal
(With Photocoupler delay
Less than
60 useconds
T1
For more information please contact Aegis Electronic Group, Inc. *(888)687-6877 *[email protected] *http://www.aegiselect.com
Aegis
Electronic
Group,
Inc.