No.16S121-03
22/64
STC-MBS891U3V / STC-MCS891U3V / STC-MBS123BU3V / STC-MCS123BU3V
Product Specifications and Use’s Guide
HR10A-7R-6PB (Hirose) or equivalent.
This connector is for the external power supply and, input and output signals.
The trigger input and sync input /output signals can be assigned through the camera setting communication.
As for the cable part (Female connector), HR10A-7P-6S (Hirose) or equivalent can be used.
Pin assignment
* Possible Maximum Rated Voltage is +24 V on CAM_RESET, GPIO0, GPIO1 and GPIO2.
* The camera operates with external power when the USB Bus power and external power supply to the
camera at same time.
* When the camera power is switching (from USB BUS power to external power, from external power to USB
BUS power), the camera resets.
Input Output DC characteristics
Pin
No.
Signal Name
Function
IN/OUT
Voltage
Current
Low Voltage
High Voltage
1
IO_GND
GND
-
-
2
GPIO2
General Purpose
Input Output
IN/OUT
IN
Less than+1.00 V
+3.00 to +24 V
4 μA (typ.) (*4)
OUT
0 to +2.20 V (*1)
+3.00 to +24 V (*2)
15 mA (Max.) (*3)
3
GPIO1
General Purpose
Input Output
IN/OUT
IN
Less than+1.00 V
+3.00 to +24 V
4 μA (typ.) (*4)
OUT
0 to +2.20 V (*1)
+3.00 to +24 V (*2)
15 mA (Max.) (*3)
4
GPIO0
General Purpose
Input Output
IN/OUT
IN
Less than+1.00 V
+3.00 to +24 V
4 μA (typ.) (*4)
OUT
0 to +2.20 V (*1)
+3.00 to +24 V (*2)
15 mA (Max.) (*3)
5
CAM_RESET
Camera
Hardware Reset
IN
IN
Less than +0.80 V
+3.00 to +24 V
4 μA (typ.) (*4)
6
CAM_PWR
Camera power
-
+8 to +24 V
-
(*1): If the current on the IO port is at 15mA when using low voltage output, the output voltage could increase for the
internal register.
(*2): This is the maximum charging voltage when the external IO port is connected.
(*3): When the external IO port is connected, control the current less than 15 mA on the IO port.
(*4): This value is the typical current value of the Input Port when High Voltage is input.
Pin No.
Signal Name
IN/OUT
1
GPIO_GND
-
2
GPIO2
IN/OUT
3
GPIO1
IN/OUT
4
GPIO0
IN/OUT
5
CAM_RESET
IN
6
CAM_PWR
-